Graco Inc 244399, 309291P Fluid Adjustment Valve Repair, Air Valve Repair

Page 33

Fluid Adjustment Valve Repair

1.Prepare the gun for service, page 24.

2.Remove the fluid adjustment valve (25). It can only be replaced as a complete assembly. See FIG. 17..

3.Screw the valve (25) into the gun handle. Torque to 15-25 in-lb (1.7-2.8 N•m).

25

TI1536A

Fig. 17. Fluid Adjustment Valve

Air Valve Repair

1.Prepare the gun for service, page 24.

2.Remove the barrel, page 29.

3.Remove the fluid adjustment valve (25) from the handle (17). Remove the spring (15). See FIG. 18..

CAUTION

Clean all parts in non-conductive solvent compati- ble with the fluid being used, such as xylol or min- eral spirits. Use of conductive solvents can cause the gun to malfunction.

Repair

4.Remove the air valve (21) with a pliers. Inspect the rubber sealing surface and replace the air valve if damaged.

CAUTION

When removing the air valve (21) be careful not to damage the seat area.The rubber seal is not removable.

5.Inspect the u-cup (6*). Do not remove the u-cup unless damaged. If removed, install the new one with its lips facing into the gun handle (17).

6.Install the air valve (21) and spring (15) into the gun handle (17).

7.Install the fluid adjustment valve (25). Torque to 15-25 in-lb (1.7-2.8 N•m).

8.Install the barrel, page 29.

25

15

21

17

*6

TI1551A

Fig. 18. Air Valve

309291P

33

Image 33
Contents II 2 G EEx 0.24 mJ PRO Xs2 Air Spray GunModel Information Table of ContentsToxic Fluid Hazard Fire, Explosion, and Electric Shock HazardPressurized Equipment Hazard Equipment Misuse HazardIntroduction How the Electrostatic Spray Gun WorksGun Overview Install the System InstallationVentilate the Spray Booth Flammable or Toxic Vapor HazardKey Typical InstallationConnect the Exhaust Tube Connect the Air LineElectric Shock Hazard Supply HoseOrifice Size Select a Fluid Nozzle and Air CapFilter the Fluid Connect the Fluid LineGrounding Check Gun Grounding Check Electrical GroundingCheck Fluid Viscosity Check Fluid ResistivityOperation Flush the Spray Gun MaintenanceTi1288a Test Gun Resistance Electrical TestsTest Power Supply Resistance Test Power Supply ResistanceElectrode Test Electrode ResistanceTroubleshooting Spray Pattern TroubleshootingProblem Cause Solution Gun Operation Troubleshooting See Test Gun Resistance on Electrical TroubleshootingSee Check Electrical Grounding on 12 and Test Gun ResistanceRepair Pressure Relief ProcedurePrepare the Gun for Service Air Cap/Nozzle Replacement Air Cap/Nozzle ReplacementElectrode Replacement Electrode ReplacementFluid Packing Removal Fluid Packing RemovalPacking Rod Packing Rod RepairBarrel Removal Barrel Installation Power Supply Power Supply Removal and ReplacementTurbine Alternator Removal and Replacement Fan Air Adjustment Valve Fan Air Adjustment Valve RepairAir Valve Repair Fluid Adjustment Valve RepairAtomizing Air Valve Atomizing Air Restrictor Valve Removal and ReplacementES ON/OFF Valve ES ON/OFF Valve RepairPart No 20 kV Electrostatic Gun, Series C PartsRef. No Alternator Qty Part No. Description Part No. DescriptionAccessories Air Line AccessoriesFluid Line Accessories Miscellaneous Accessories Gun AccessoriesCategory Data Technical DataGraco Information Graco Standard Warranty