Graco Inc 258732, 7900HD, 3A0242A, 258737, 258738, 258736, 258734, 258731 Hose Reel, Clearing Tip Clogs

Page 9

Clearing Tip Clogs

1.Release trigger, put safety ON. Rotate SwitchTip. Take safety OFF. Trigger gun to clear clog. Never point gun at your hand or into a rag!

ti10166a

ti13033a

ti10167a

 

2.Put safety ON. Return SwitchTip to original position. Take safety OFF and continue spraying.

ti10166a

ti13034a

ti10167a

 

 

WatchDogProtection System (Not Available on All Units)

Pump stops automatically when material pail is empty.

To Activate:

1.Perform Startup.

2.Premium units with digital display:

Turn WatchDog switch ON and WD ON displays. EMPTY displays/flashes and pump stops when Watchdog protection system detects an empty material pail.

ti6224a

TI

3.Turn WatchDog switch OFF. Add material or reprime sprayer. Turn pump switch OFF and ON to reset WatchDog protection system. Turn WatchDog switch back ON to continue to monitor material level.

WatchDogProtection System (Not Available on All Units)

Hose Reel

Be sure to keep your head clear of hose reel while winding up hose.

1. Make sure hose is routed through hose guide.

ti13504a

2.Lift and turn pivot lock 90 to unlock hose reel. Pull on hose to remove it from hose reel.

ti13501a

3.Pull reel handle down and turn clockwise to reel in hose.

ti13502a

ti13503a

NOTE: The hose reel can be locked into two posi-

tions: Usage (A) and Storage (B).

(A)(B)

ti13563a

3A0242A

9

Image 9
Contents Operation Fire and Explosion Hazard Pressurized Aluminum Parts Hazard Component Identification Setup Pressure Relief ProcedureConvertible Models Only SEC StartupSwitch Guard Assembly Clearing Tip Clogs Hose ReelOperation Main Menu Digital Tracking SystemSecondary Menu Stored Data WatchDog Pump Protection Modes Cleanup 3A0242A 3A0242A 3A0242A For Graco Canada Customers Graco Standard Warranty