Cleanup
Cleanup
6. Turn prime valve forward to SPRAY position. Trigger gun into flushing pail to purge fluid from hose.
1.Perform Pressure Relief Procedure (page 5), steps 1 - 4. Remove siphon tube set from paint and place in flushing fluid. Remove tip guard from gun.
ti14845a
ti14847a
ti14844a
NOTE: Use water for
2.Turn power ON. Turn prime valve forward to SPRAY position.
ti4266a
ti14845a
3.Increase pressure to 1/2. Hold gun against paint pail. Take trigger safety OFF. Trigger gun until flush- ing fluid appears.
1/2
ti14846a
ti4271a
4.Move gun to waste pail, hold gun against pail, trig- ger gun to thoroughly flush system. Release trigger and put trigger safety ON.
ti14847a
5.Turn prime valve down to DRAIN position and allow flushing fluid to circulate until flushing fluid appears clear.
7.Raise siphon tube above flushing fluid and run sprayer for 15 to 30 seconds to drain fluid. Turn power OFF
PAINT
ti2820a
FLUSH
8.Turn prime valve down DRAIN position. Unplug sprayer.
ti2718a
ti14842a
9.Remove filters from gun and sprayer, if installed. Clean and inspect. Install filters.
ti15018a
10.If flushing with water, flush again with mineral spirits, or Pump Armor, to leave a protective coating to pre- vent freezing or corrosion.
11.Wipe sprayer, hose and gun with a rag soaked in water or mineral spirits.
ti2776a
12 | 3A0242A |