AA30 Air Assisted Spray Gun
Models: 257096, RAC Tip; 257380, Flat Tip
Maximum Working Pressure: 3600 psi (248 bar, 24.8 MPa)
Maximum Air Working Pressure: 100 psi (7 bar, 0.7 MPa)
English
Important Safety Instructions
Refer to your sprayer instruction manual for Pressure Relief and spray instructions. Keep these instructions.
ti12849a
313347C
- For the application of architectural paints and coatings -
The following Warnings are for the setup, use, grounding, maintenance and repair of this equipment. The exclamation point symbol alerts you to a general warning and hazard symbols refer to
WARNINGS
SKIN INJECTION HAZARD
immediate surgical treatment.
•Do not point gun at anyone or at any part of the body.
•Do not put your hand over the spray tip.
•Do not stop or deflect leaks with your hand, body, glove, or rag.
•Do not spray without tip guard and trigger guard installed.
•Engage trigger lock when not spraying.
•Follow Pressure Relief Procedure in this manual, when you stop spraying and before cleaning, checking, or servic- ing equipment.
FIRE AND EXPLOSION HAZARD
Flammable fumes, such as solvent and paint fumes, in work area can ignite or explode. To help prevent fire and explosion:
•Use equipment only in well ventilated area.
•Eliminate all ignition sources; such as pilot lights, cig- arettes, portable electric lamps, and plastic drop cloths (potential static arc).
•Keep work area free of debris, including solvent, rags and gasoline.
•Do not plug or unplug power cords, or turn power or light switches on or off when flammable fumes are present.
•Ground all equipment in the work area. See Ground- ing instructions.
•Use only grounded hoses.
•Hold gun firmly to side of grounded pail when trigger- ing into pail.
•If there is static sparking or you feel a shock, stop operation immediately. Do not use equipment until you identify and correct the problem.
•Keep a working fire extinguisher in the work area.
EQUIPMENT MISUSE HAZARD
Misuse can cause death or serious injury.
•Do not operate the unit when fatigued or under the influence of drugs or alcohol.
•Do not exceed the maximum working pressure or temperature rating of the lowest rated system compo- nent. See Technical Data in all equipment manuals.
•Use fluids and solvents that are compatible with equip- ment wetted parts. See Technical Data in all equip- ment manuals. Read fluid and solvent manufacturer’s warnings. For complete information about your mate- rial, request MSDS forms from distributor or retailer.
•Check equipment daily. Repair or replace worn or damaged parts immediately with genuine manufac- turer’s replacement parts only.
•Do not alter or modify equipment.
•Use equipment only for its intended purpose. Call your distributor for information.
•Route hoses and cables away from traffic areas, sharp edges, moving parts, and hot surfaces.
•Do not kink or over bend hoses or use hoses to pull equipment.
•Keep children and animals away from work area.
•Comply with all applicable safety regulations.
PRESSURIZED ALUMINUM PARTS HAZARD
Do not use
use can cause serious chemical reaction and equipment rup- ture, and result in death, serious injury, and property damage.
PERSONAL PROTECTIVE EQUIPMENT
You must wear appropriate protective equipment when operating, servicing, or in the operating area of the equipment to help protect you from serious injury. This equipment includes but is not limited to:
• Protective eyewear and hearing protection Gloves, clothing and respirator as recommended by the fluid and solvent manufacturer
Graco Inc. P.O. Box 1441 Minneapolis, MN
Copyright 2009, Graco Inc. is registered to I.S. EN ISO 9001