Loss of Air Pressure

Loss of Air Pressure

Purge rod actuation is controlled by air pressure. In event of loss of air pressure, the purge rod will remain retracted, the impingement ports will remain open, and the gun will continue to pour. To stop pouring, do one of the following:

Engage piston safety lock, see Piston Safety Lock section

Close fluid valves A and B, see FIG. 3

TI14457a

FIG. 3

Hook Support

If necessary, use the hook support located on the top of the gun to support the weight of the gun. Connect a strong rope or chain able to support the weight of the gun to the hook, then connect the other end to a sup- port. This will enable the user to use the gun without having to support the weight of the gun.

TI14450a1

14

313872B

Image 14
Contents Important Safety Instructions EP GunContents Related Manuals Orifice Flow Area Ratio Chart ModelsFixed Orifice Flowrate Data EP Fixed Orifice Flow DataFlowrate gpm Variable Orifice Flowrate DataOrifice Diameter Variable Orifice Flowrate Data 1500 PSI Variable Orifice Flowrate Data 2000 PSI Toxic Fluid or Fumes Hazard Fire and Explosion Hazard Important Two-Component Material Information Changing Materials Red and B Blue ComponentsGrounding Piston Safety LockThroat Seal Liquid Trigger LockLoss of Air Pressure Hook SupportHook Support 313872B Component Identification KeyCutaway View Gun Detriggered Theory of OperationGun Triggered Fluid Pouring Setup Order to increase the pressure, turn the needle clockwise Adjust OrificesPerform Bleed Throat Seal Liquid Cartridge pro- cedure. See Follow Pressure Relief Procedure, Optional Hose PositionPressure Relief Procedure Short Term Shutdown Perform Pressure Relief Procedure onShutdown Long Term ShutdownLubrication MaintenanceSupplied Tool Kit Bleed Throat Seal Liquid CartridgeClean Outside of Gun Flush GunFollow Pressure Relief Procedure Clean Breather PlugClean Fluid Manifold Clean Check Valves Remove Front End, see Clean Fluid Housing PassagesFollow Pressure Relief Procedure on Clean Orifice Replace Mix Chamber and Front Seal Perform Replace Throat Seal Liquid Cartridge,Replace Throat Seal Liquid Cartridge RepairTools Required Perform Bleed Throat Seal Liquid Cartridge pro- cedure, see Perform Pressure Relief Procedure, Remove Front EndDisassemble Front End Assemble Front EndPistons and Bulkhead See Attach Front End procedureAttach Front End Access Pistons Bulkhead Shaft Purge Rod Solenoid Valve 26-3.39 Nm. See Component Identification onTroubleshooting Problem Cause SolutionProblem Cause Solution Electrical Diagram Parts Model 257999 ShownOrifice, Auto Hand-Held RingOrifice, Auto Hand-Held Kits on KitsSee Orifice Orifice 24C751 Orifice Housing 24C756 Ring 24C805 24C815 Kits Kits Located inside back cap Model Iso Model Polyol Orifice Kit Orifice KitsImpingement Kit Type and Kit Number Kit Illustration Drill Bit KitsKit Drill Bit Qty Orifice Size Number Complete O-ring Placement Guide Ref PartAccessories 248299 5.0 gal liter Pail Solvent Flush Canister KitSolvent Flush Pail Kit Technical Data Models without Handle 6.4 lb 2.9 kgDimensions Ref Dimension, in. mmTechnical Data 313872B Graco Standard Warranty Graco Information