Graco Inc 24C932, 313872B, 257999, 24C934, 24C933, TI14450a Troubleshooting, Problem Cause Solution

Page 39

Troubleshooting

Troubleshooting

Follow Pressure Relief Procedure, page 22, before checking or repairing gun.

NOTICE

To prevent cross-contamination of the equipment’s wet- ted parts, never interchange component A (isocyanate) and component B (resin) parts. The gun is shipped with the A side on the left. The fluid manifold, fluid housing, side seal assembly, check valve cartridge, and mix chamber are marked on the A side.

Use the following table to check all possible problems and causes before disassembling gun. See Mainte- nance on page 24 and Repair on page 31 for refer- enced procedures.

Problem

Cause

Solution

 

 

 

Gun does not fully actuate when trig-

Safety lock engaged

Disengage piston safety lock

gered

 

 

Plugged breather plug

Clean breather plug

 

 

 

 

Damaged air valve

Replace if necessary

 

 

 

Fluid does not pour when gun is fully

Closed fluid valves

Open valves.

actuated

 

 

Plugged orifice ports

Clean orifice ports

 

 

 

 

Plugged check valves

Clean check valves

 

 

 

 

Safety lock engaged

Disengage piston safety lock

 

 

 

Gun actuates slowly

Plugged breather plug

Clean breather plug

 

 

 

 

Damaged piston o-rings

Replace air piston o-rings

 

 

 

 

Damaged air gasket

Replace

 

 

 

 

Dirty or damaged air valve

Clean or replace valve

 

 

 

Gun delays, then actuates abruptly

Cured material around the purge rod

Inspect purge rod, mix module, and

 

 

orifices. Replace if necessary

 

 

 

 

Empty TSL cartridge

Replace cartridge

 

 

 

Gun does not actuate when triggered

Air supply to gun is shut off

Open air supply

 

 

 

 

Foam build-up around front tip

1) Clean off front tip.

 

 

2) Use 3/4 in. wrench to loosen front

 

 

tip 1/8 turn and re-tighten.

 

 

 

 

Signal cable is disconnected

Connect signal cable

 

 

 

Pressure imbalance

Plugged orifice ports

Clean orifice ports

 

 

 

 

Plugged check valves

Clean check valves

 

 

 

 

Viscosities not equal

Adjust temperature or orifice needle

 

 

to compensate

 

 

 

 

Plugged fluid screens

Clean screens

 

 

 

313872B

39

Image 39
Contents EP Gun Important Safety InstructionsContents Related Manuals Models Orifice Flow Area Ratio ChartEP Fixed Orifice Flow Data Fixed Orifice Flowrate DataVariable Orifice Flowrate Data Orifice DiameterFlowrate gpm Variable Orifice Flowrate Data 1500 PSI Variable Orifice Flowrate Data 2000 PSI Toxic Fluid or Fumes Hazard Fire and Explosion Hazard Important Two-Component Material Information Red and B Blue Components Changing MaterialsTrigger Lock Piston Safety LockThroat Seal Liquid GroundingHook Support Loss of Air PressureHook Support 313872B Key Component IdentificationCutaway View Theory of Operation Gun Triggered Fluid PouringGun Detriggered Setup Adjust Orifices Perform Bleed Throat Seal Liquid Cartridge pro- cedure. SeeOrder to increase the pressure, turn the needle clockwise Optional Hose Position Follow Pressure Relief Procedure,Pressure Relief Procedure Long Term Shutdown Perform Pressure Relief Procedure onShutdown Short Term ShutdownBleed Throat Seal Liquid Cartridge MaintenanceSupplied Tool Kit LubricationFlush Gun Clean Outside of GunClean Breather Plug Clean Fluid ManifoldFollow Pressure Relief Procedure Clean Check Valves Clean Fluid Housing Passages Follow Pressure Relief Procedure onRemove Front End, see Clean Orifice Perform Replace Throat Seal Liquid Cartridge, Replace Mix Chamber and Front SealRepair Tools RequiredReplace Throat Seal Liquid Cartridge Perform Bleed Throat Seal Liquid Cartridge pro- cedure, see Remove Front End Perform Pressure Relief Procedure,Assemble Front End Disassemble Front EndSee Attach Front End procedure Attach Front EndPistons and Bulkhead Access Pistons Bulkhead Shaft Purge Rod 26-3.39 Nm. See Component Identification on Solenoid ValveProblem Cause Solution TroubleshootingProblem Cause Solution Electrical Diagram Model 257999 Shown PartsRing Orifice, Auto Hand-HeldOrifice, Auto Hand-Held Kits See OrificeKits on Orifice 24C751 Orifice Housing 24C756 Ring 24C805 24C815 Kits Kits Located inside back cap Orifice Kits Impingement Kit Type and Kit NumberModel Iso Model Polyol Orifice Kit Drill Bit Kits Kit Drill Bit Qty Orifice Size NumberKit Illustration Ref Part Complete O-ring Placement GuideAccessories Solvent Flush Canister Kit Solvent Flush Pail Kit248299 5.0 gal liter Pail Models without Handle 6.4 lb 2.9 kg Technical DataRef Dimension, in. mm DimensionsTechnical Data 313872B Graco Information Graco Standard Warranty