Setup
Setup
At least one hose must provide a static ground to the gun.
Connect Air and Fluid Lines
1.Shut off the air supply.
2.Install a shutoff valve (not supplied) down- stream of the air regulator to shut off gun air.
3.Install an inline air filter (not supplied) to clean and dry the gun air supply.
4.Connect a clean, dry, filtered air supply to the air inlet fitting. See FIG. 1.
• Recommended 5/16 in. (7.9 mm) ID hose, optional 3/8 in. (9.5 mm) ID hose.
•Check that your shop air provides ade- quate air flow. See Technical Data, page 23, for minimum cfm requirements.
•Set shop air pressure regulator (not supplied) according to fluid manufac- turer’s recommendation. See maximum compliant air pressure on air cap.
•Make sure no air restrictions, such as
5.Connect a fluid hose to the fluid inlet fitting. See FIG. 1.
| air inlet | fluid inlet |
|
| |
FIG. 1 |
| ti11094a |
|
|
|
6.Connect other end of the fluid hose to a regulated fluid supply line.
Ground the Gun
Check your local electrical code and pump manual for detailed grounding instructions.
Ground the spray gun through connection to a
Flush Before Using Equipment
The equipment was tested with lightweight oil, which is left in the fluid passages to protect parts. To avoid contaminating your fluid with oil, flush the equipment with a compatible sol- vent before using the equipment. See Flush, page 10.