Graco Inc 312414J important safety instructions Reassembly

Page 15

Reassembly

1.Install air control valve assembly (5) with valve turned fully counterclockwise to out- ermost position. Torque to 85-90 in-lb (9.6-10.2 N•m).

2.Install air inlet valve assembly (27) with valve turned fully counterclockwise to out- ermost position. Torque to 205-215 in-lb (23.2-24.3 N•m).

3.Lubricate u-cup spreader (15) and u-cup packing (16). Install spreader (15) with tapered end facing rear of gun. Install u-cup packing (16) with open end facing front of gun. Install packing nut (17). Torque to

3 in-lb (0.3 N•m).

ti11226a

17 16 15

Repair

4.Install wave washer (18) with cupped side toward the gun body. Lubricate and apply thread retainer to trigger pin (10). Install trigger (10), trigger pin (21), and trigger nut (22). Torque to 15-20 in-lb

(1.7-2.3 N•m).

5.Install air valve assembly (6), spring (28), and nut (7). Torque to 175-185 in-lb (19.8-20.9 N•m).

6.Install needle (9) and spring (26). Lightly lubricate and install fluid control valve (8).

7.Trigger gun while replacing nozzle (11). Torque to 155-165 in-lb (17.5-18.6 N•m).

8.Install air cap assembly (13) and retaining ring (14).

312414J

15

Image 15
Contents AirPro Pressure Feed Airspray Gun Important Safety InstructionsContents Automotive ModelsMetal Spray Guns Metal with Stainless Steel TipAdhesives StainWaterborne High WearFire and Explosion Hazard Compliant Guns Gun SelectionConventional Guns Hvlp GunsGround the Gun SetupFlush Before Using Equipment Connect Air and Fluid LinesAdjust Spray Pattern Volatile Organic Compounds VOC Regulation Pressure Relief ProcedureOperation Apply FluidDaily Gun Maintenance General TasksFlush Compliant Cleaning Methods Clean GunWrong TroubleshootingProblem Cause Solution RightTroubleshooting Disassembly Follow Pressure Relief Procedure,Repair Reassembly Parts Needle Part Description QtyParts Part No. Description AccessoriesRepair Kits General Metal Spray GunsGeneral Metal with Stainless Steel Tip Air Brush AutomotiveStain SpatterWaterborne High WearNeedle Tips Technical Data Air Inlet PressureSpray Type Application Psi MPa, bar Scfm Graco Information Graco Standard Warranty