Graco Inc 308972 manual 7876A

Page 14

Replacing the Hydraulic Pump

1.Follow the Pressure Relief Procedure Warning on page 10. Let the hydraulic system cool before beginning the service procedure.

2.Unscrew the reservoir drain plug (51, page 24), having a container ready to catch the draining fluid.

3.Disconnect the hose (7) from the bypass valve (9) by loosening the hose clamp (8). See Fig 8.

4.Loosen the hose clamp (8) and pull the hose (85) off the hose insert (5) near the elbow (3). See Fig 8.

5.Loosen the hose clamp (54) on the hose (53) just above the hydraulic pump (107). See Fig 8.

6.Loosen the tube fitting nut (18) of hose (22). See Fig 8.

7.Remove the two capscrews (150), lockwashers (66) and washers (64) holding the pump (107) to the support (117). See Fig 8.

8.Pull the pump straight off the pump support.

9.Loosen the setscrews (108) on the pump half of the coupler (109). See Fig 9.

10.Remove all fittings from the old pump and install them on the new pump in the same order.

11.Check Dimension A as shown in Fig 9. When the dimension is correct, tighten the setscrews (108), slide the new pump assembly onto the pump support (117) and recheck the dimension.

CAUTION

The correct coupling dimension is critical to avoid improper coupler engagement to the coupler spider which will damage the coupler and make the sprayer inoperable.

12.Reconnect the hoses. Reinstall the reservoir plug (51, page 24)), and refill the reservoir with clean, Graco approved hydraulic oil.

5

3

113

112

117

85

853

152

54

52

4

7

 

 

 

8

 

 

 

9

 

 

 

 

 

 

108

 

 

 

109

 

 

 

114

 

 

 

115

 

22

 

49,66

 

 

107

 

 

 

 

 

 

150,66,64

Fig 8

 

18

7876A

 

 

 

 

 

14308972

Image 14
Contents Read and Keep for Reference 308972This manual contains important warnings and information ModelTable of Contents SymbolsInjection Hazard Fire and Explosion Hazard Fire Skin Injection Explosion HazardConnect the Hose and Gun SetupComponent Identification Check the Engine Oil Level Grade of OIL ChartCheck the Hydraulic Oil Level Grounding Fire and Explosion HazardFlushing When to FlushHow to Flush Startup after storageFlushing Prepare the Fluid Pressure Relief ProcedureOperation Starting the Sprayer Prime the Pump Cleaning a Clogged Tip Adjusting the Intake Valve Ball Travel Maintenance Troubleshooting Problem7876A Dimension a 0.05º Mm ±0.254 108 BReconnecting the Displacement Pump Displacement Pump Service210±208 Displacement Pump Disconnect the Displacement Pump Relieve the pressure GH5030 Roof Rig Parts Drawing GH3640 Roof Rig Parts Drawing GH2560 Roof Rig Parts Drawing GH2075 Roof Rig Parts Drawing GH1015 Roof Rig Parts Drawing Roof Rigs Sprayer Parts Drawing Models 687100, 687327 965171 9651657879A Roof Rigs Parts List Description QTYPage Graco Phone Number Technical DataAccessories GRACO±APPROVED Hydraulic FluidFor Graco Canada Customers Graco WarrantyAdditional Warranty Coverage