Graco Inc 308-425, 237-296 dimensions Fire and Explosion Hazard

Page 4

WARNING

FIRE AND EXPLOSION HAZARD

Improper grounding, poor ventilation, open flames or sparks can cause a hazardous condition and result in a fire or explosion and serious injury.

DGround the equipment and the object being sprayed. Refer to Grounding on page 5.

DIf there is any static sparking or you feel an electric shock while using this equipment, stop spray- ing immediately. Do not use the equipment until you identify and correct the problem.

DProvide fresh air ventilation to avoid the buildup of flammable fumes from solvents or the fluid being sprayed.

DKeep the spray area free of debris, including solvent, rags, and gasoline.

DElectrically disconnect all equipment in the spray area.

DExtinguish all open flames or pilot lights in the spray area.

DDo not smoke in the spray area.

DDo not turn on or off any light switch in the spray area while operating or if fumes are present.

DDo not operate a gasoline engine in the spray area.

TOXIC FLUID HAZARD

Hazardous fluid or toxic fumes can cause serious injury or death if splashed in the eyes or on the skin, inhaled, or swallowed.

DKnow the specific hazards of the fluid you are using.

DStore hazardous fluid in an approved container. Dispose of hazardous fluid according to all local, state and national guidelines.

DAlways wear protective eyewear, gloves, clothing and respirator as recommended by the fluid and solvent manufacturer.



Image 4
Contents INSTRUCTIONS-PARTS List Table of ContentsSymbols List of ModelsInjection Hazard Cal attentionFire and Explosion Hazard General Information SetupPrepare the Operator Prepare the Site Grounding Supplied Components Connect the Fluid Hoses and GunDetail of Air Line Connection and Air Regulation Kit Pressure Relief Procedure Using the Airless Spray GunOperation Packing Nut/Wet-CupPrime the Pump Set the Air and Fluid PressureFlushing Shutdown and Care of the PumpRelieve the pressure Detail of Air Line Connection Parts Description Qty Part No -281, Series B High Pressure Surge Tank 102 106 104 10512 103 25 Ref Manual Change Summary Technical Data Sound Pressure Levels dBaCategory Data Input Air Pressures at 15 cycles per minuteDimensions Pump Model Width AcrossGraco Phone Numbers Graco Warranty and DisclaimersToll Free