Graco Inc 308-425, 237-296 dimensions Operation, Pressure Relief Procedure, Packing Nut/Wet-Cup

Page 8

Operation

Pressure Relief Procedure

WARNING

INJECTION HAZARD

The system pressure must be manually relieved to prevent the system from starting or spraying accidentally. Fluid

under high pressure can be injected through the skin and cause serious injury. To reduce the risk of an injury from injection, splashing fluid, or moving parts, follow the Pressure Relief Procedure whenever you:

Dare instructed to relieve the pressure,

Dstop spraying,

Dcheck or service any of the system equipment,

Dor install or clean the spray tips.

1.Lock the gun trigger safety.

2.Close the red-handled bleed-type master air valve (F, required in your system).

3.Unlock the gun trigger safety.

4.Hold a metal part of the gun firmly to the side of a grounded metal pail, and trigger the gun to relieve pressure.

5.Lock the gun trigger safety.

6.Open the drain valve (D, required in your system), having a container ready to catch the drainage.

7.Leave the drain valve open until you are ready to spray again.

If you suspect that the spray tip or hose is completely clogged, or that pressure has not been fully relieved after following the steps above, very slowly loosen the tip guard retaining nut or hose end coupling and relieve pressure gradually, then loosen completely. Now clear the tip or hose.

Packing Nut/Wet-Cup

Before starting, fill the packing nut (K) 1/3 full with Graco Throat Seal Liquid (TSL) or compatible solvent. See Fig. 3.

WARNING

To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure at left.

The packing nut is torqued at the factory and is ready for operation. If it becomes loose and there is leaking from the throat packings, relieve pressure, then torque the nut to 100–110 ft-lb (136–149 N.m) using the supplied wrench. Do this whenever necessary. Do not overtighten the packing nut.

Flush the Pump Before First Use

The pump is tested with lightweight oil, which is left in to protect the pump parts. If the fluid you are using may be contaminated by the oil, flush it out with a compatible solvent. See Flushing on page 10.

Using the Airless Spray Gun

Before operating the equipment, read the instruction manual supplied with the gun.

Spray some test patterns before doing any finished work. Refer to the gun manual for detailed information on correct spraying technique.



Image 8
Contents INSTRUCTIONS-PARTS List Table of ContentsSymbols List of ModelsInjection Hazard Cal attentionFire and Explosion Hazard Prepare the Operator Prepare the Site Grounding SetupGeneral Information Supplied Components Connect the Fluid Hoses and GunDetail of Air Line Connection and Air Regulation Kit Pressure Relief Procedure Using the Airless Spray GunOperation Packing Nut/Wet-CupPrime the Pump Set the Air and Fluid PressureRelieve the pressure Shutdown and Care of the PumpFlushing Detail of Air Line Connection Parts Description Qty Part No -281, Series B High Pressure Surge Tank 102 106 104 10512 103 25 Ref Manual Change Summary Technical Data Sound Pressure Levels dBaCategory Data Input Air Pressures at 15 cycles per minuteDimensions Pump Model Width AcrossToll Free Graco Warranty and DisclaimersGraco Phone Numbers