Graco Inc 308-425, 237-296 dimensions Shutdown and Care of the Pump, Flushing, Relieve the pressure

Page 10

Operation

Shutdown and Care of the Pump

WARNING

To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 8.

For overnight shutdown, stop the pump at the bottom of its stroke to prevent fluid from drying on the ex- posed displacement rod and damaging the throat packings. Relieve the pressure.

Always flush the pump before the fluid dries on the displacement rod. See Flushing below.

Flushing

WARNING

FIRE AND EXPLOSION HAZARD Before flushing, read the section FIRE OR EXPLOSION HAZARD on page 4. Be sure the entire system and flushing pails are properly grounded. Refer to Grounding on page 5.

Flush the pump:

DBefore the first use

DWhen changing colors or fluids

DBefore fluid can dry or settle out in a dormant pump (check the pot life of catalyzed fluids)

DBefore storing the pump.

Flush with a fluid that is compatible with the fluid you are pumping and with the wetted parts in your system. Check with your fluid manufacturer or supplier for recommended flushing fluids and flushing frequency.

CAUTION

Never leave water or water-base fluid in the pump overnight. If you are pumping water-base fluid, flush with water first, then with a rust inhibitor such as mineral spirits. Relieve the pressure, but leave the rust inhibitor in the pump to protect the parts from corrosion.

WARNING

To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 8.

1.Relieve the pressure.

2.Remove the tip guard and spray tip from the gun. See the gun instruction manual.

3.Remove the filter element from the fluid filter (4) or surge tank. Reinstall the filter or surge tank bowl.

4.Place the suction tube (7) in a container of solvent.

5.Hold a metal part of the gun firmly to the side of a grounded metal pail.

6.Start the pump. Always use the lowest possible fluid pressure when flushing.

7.Trigger the gun.

8.Flush the system until clear solvent flows from the gun.

9.Relieve the pressure.

10.Clean the tip guard, spray tip, and fluid filter ele- ment separately, then reinstall them.

11.Clean the inside and outside of the suction tube

(7).

1￿ 3￿8￿425

Image 10
Contents INSTRUCTIONS-PARTS List Table of ContentsSymbols List of ModelsInjection Hazard Cal attentionFire and Explosion Hazard General Information SetupPrepare the Operator Prepare the Site Grounding Supplied Components Connect the Fluid Hoses and GunDetail of Air Line Connection and Air Regulation Kit Operation Pressure Relief ProcedureUsing the Airless Spray Gun Packing Nut/Wet-CupPrime the Pump Set the Air and Fluid PressureFlushing Shutdown and Care of the PumpRelieve the pressure Detail of Air Line Connection Parts Description Qty Part No -281, Series B High Pressure Surge Tank 102 106 104 10512 103 25 Ref Manual Change Summary Category Data Technical DataSound Pressure Levels dBa Input Air Pressures at 15 cycles per minuteDimensions Pump Model Width AcrossGraco Phone Numbers Graco Warranty and DisclaimersToll Free