Component Testing | Procedures | '1 |
To avoid risk of electrical shock, personal injury, or death, disconnect power to oven before servicing, unless | ||
ftesting requires it. | WARNING |
nlustration |
| Component |
31823701 |
| Oven light socket |
31722801 |
| Oven indicator light |
|
| and |
|
| Surface indicator light |
301491 |
| Rocker switch |
W | Coil surface elements | |
W | 6" and 8" | |
31730101 |
| Coil surface terminal |
|
| block |
Test Procedure
Test continuityof receptacle terminals.
Remove one lead from switch terminal and measure resistance across terminals.
Measure voltage at indicator light.
Measure continuityof switch
positions: Closed
Open
Test continuityof terminals.
Remove element and turn surface
element on and test for voltage at terminal block.
Results
Indicates continuitywith bulb screwed in.
If not replace. Switch closed: 0
Switch open: Infinite resistance
]f voltage is present and lightdoes not operate. Replace light.
If no voltage is present at indicatorlight check widng.
Continuity, if not replace.
Intinife, if not replace.
Continuity, if not replace.
240VAC
31846201Ribbon surface thermal limiter/hot
light switch
059552 | I Bake element |
|
061732 | Broil element |
314907 | Oven temperature |
| sensor |
31891202 | Infinite switch |
Remove one wire lead from element and measure resistanceof the
element,
Tum surface element on and test for
voltage. See wiring diagram and schematic.
Disconnect leads and measure resistance on the following:
Disconnect wire leads to element and measure resistance of terminals.
Measure voltage at bake element.
Disconnect wire leads to element and measure resistance of terminals.
Measure voltage at broilelement.
Measure resistance.
Remove wiring from terminals H1 and H2. Connect Volt ohms meter to
H1 and H2.
Measure the followingfor voltages at LO, MED, HI:
H1 to H2
Continuity, if not replace.
1200W: 45 to 51
t50OW: 36 to 41
200OW: 27 to 31
2500W: 21 to 25
240 VAC
Etectmv_
Continuity, approximately 23 Q, if not replace.
240VAC, see wiring diagram for terminal identification.
If no voltage is present at bake element check widng.
Continuity, approximately 19 £_, if not replace.
240VAC, see wiring diagram for terminal identification.
If no voltage is present at broilelement
check widng.
Approximately 1100 _ at room
temperature 75°F. |
| |
Time On | Time Off | |
LO | 5% | 95% |
MED | 50% | 50% |
HI | 100% | 0% |
240 VAC, if not replace switch.
RT2320003 Rev. 9 | 2 | Apd11999 |