Component Testing Procedures
ILTo avoid risk of electrical shock, personal injury, or WARNINGdeath, disconnect power testing requires it.
to oven before servicing, unless '1
IllustraUon
ERC3 Controlled
ERC3 Controlled
ERC3 Controlled
ERC3 Controlled
Component
ERC3 - Touchmatic
electronic range control
Oven temperature adjustment
Twelve hour off
Child lock out
Drive requirements Based on a 60
second cycle.
Test Procedure
F4_Shorted circuit in oven temperature circuit.
Push BAKE pad.
Push SLEWpad until an oven temperature greater than 500°F displays.
IImmediately push and hold BAKEpad until "00" displays,approximately 5 seconds.
To decrease oven teroperatara (for a cooler oven), Push SLEWpad until negative numbers appear, Oven can be adjusted from
To increase oven temperature (for a warmer oven), Push SLEWped until positive numbers appear. Oven can be adjusted from 5" to 35 ° higher. To avoid
over adjusting oven move temperature 5° each time.
Push OVEN CANCEL button. Temperature adjustment will be retained even through a powerfailure. Control will automatically cancel any cooking operationand remove all relay ddves 12 hoursafter the last pad touch. Control input features will be disabled and display will indicate"OFF", when BAKE and CLOCK are pushed simultaneouslyand held for 5 seconds. Control will return to normal operat on
by repeating the procedure. Bake
Broil
Clean
Stage 1
Stage 2
Lock light
Results Verify actuator operation.
Check sensorwidng, sensor, and temperature limiter,
Check sensor resistance and wiring.
Check sensor resistance and widng.
Replace ERC3.
Check latch switch and door motor.
Check latch switch and door motor.
Vedfy operation of door latch switches.
While increasingor decreasing oven temperature, this does not affect self-
cleaning temperature.
100% bake 10°1,broil
0O,_bake, 100% broil HI
0% bake 93% broil 5
0% bake 87% broil 4
0% bake 80% broil 3
0% bake 73% bmil 2
0% bake 57"/,,broil 1
Time controlled 15 minutes 0% bake 100% broil.
Time controlled 100% bake 10o/obroil. On at the startof the clean cycle.
Off at approximately 400°F + 25°F.
RT2320003 Rev. 9 | 4 | Apd11999 |