Component Testing Information
I
To avoid risk of electrical shock, personal injury, or death, diSconnect power to oven before servicing, unless | ||||
I I | iL |
| WARNING |
|
testing requires |
|
|
| |
Illustration | Component |
| Test Procedure | Results |
053584 | Control limit | Normally Closed |
| |
|
| Verify proper operation. |
| |
|
| Closed | 245°F | Continuity |
|
| Open | 275°F | Infinite |
|
|
|
| If open at room temperature, replace. |
065780 | Door lock switch |
305797 | Door plunger switch |
Carefully open the hinge fully, and insert a wooden dowel or screwdriver
bit into opening.
Remove top and bottom screws
:securing hinge.
Slide hinge top towards rear of unit and guide hinge out through frame opening or storage drawer.
Switch connection in following
positions: Unlooked Looked
;et ERC to Clean
Remove switch from unit and measure the following points:
C-NC
CNO
I | 4_ CAUTION | II | I |
Do not place hands in hinge area when | |||
Oven door is removed. Hinge can snap | |||
closed and pinch hands or fingers. |
|
Lock LED should flash
Look LED and Oven LED should illuminate, If Lock LED does not illuminate,check switch and widng.
Plunger in infinite, Plunger out continuity. Plunger in continuity, Plunger out infinite.
31797301 | Autotatch assembly | Disconnect wires and test for | NC | NC |
|
|
|
| |||
| with door plunger | continuityper diagram | __, ,_ |
|
|
| switch |
|
|
| |
|
|
|
|
| |
|
|
| ,:....a_H. .....___.o_ | _.. | ; |
April 1999 | 3 | RT2320003 Rev 9 |