Component Testing Information

Component Testing Information

I

To avoid risk of electrical shock, personal injury, or death, diSconnect power to oven before servicing, unless

I I

iL

 

WARNING

 

testing requires

 

 

 

Illustration

Component

 

Test Procedure

Results

053584

Control limit

Normally Closed

 

 

 

Verify proper operation.

 

 

 

Closed

245°F

Continuity

 

 

Open

275°F

Infinite

 

 

 

 

If open at room temperature, replace.

31715201--LHHinge

31715202--RH

065780

Door lock switch

305797

Door plunger switch

Carefully open the hinge fully, and insert a wooden dowel or screwdriver

bit into opening.

Remove top and bottom screws

:securing hinge.

Slide hinge top towards rear of unit and guide hinge out through frame opening or storage drawer.

Switch connection in following

positions: Unlooked Looked

;et ERC to Clean

Remove switch from unit and measure the following points:

C-NC

CNO

I

4_ CAUTION

II

I

Do not place hands in hinge area when

Oven door is removed. Hinge can snap

closed and pinch hands or fingers.

 

COM-NO=Open, COM-NC=Closed

COM-NO=Clceed, COM-NC--Open

Lock LED should flash

Look LED and Oven LED should illuminate, If Lock LED does not illuminate,check switch and widng.

Plunger in infinite, Plunger out continuity. Plunger in continuity, Plunger out infinite.

31797301

Autotatch assembly

Disconnect wires and test for

NC

NC

 

 

 

 

 

with door plunger

continuityper diagram

__, ,_

 

 

 