Desa 30 Installation, Continued, Installing Logs, Pressure Testing Heater Gas Connections

Models: R, V, T 30

1 40
Download 40 pages 14.56 Kb
Page 14
Image 14
Pressure Testing Heater Gas Connections

14

INSTALLATION

Checking Gas Connections (Cont.) Installing Logs

INSTALLATION

Continued

Pressure Testing Heater Gas Connections

1.Open equipment shutoff valve (see Figure 18).

2.Open main gas valve located on or near gas meter for natural gas or open propane/LP supply tank valve.

3.Make sure control knob of heater is in the OFF position.

4.Check all joints from equipment shutoff valve to thermostat gas valve (Thermostat-Controlled Models), to control valve (Manually-Controlled Models), or to gas control (Remote- Ready Models) (see Figures 19 and 20). Apply noncorrosive leak detection fluid to all joints. Bubbles forming show a leak.

5.Correct all leaks at once.

6.Light heater (see Operating Heater, pages 16 through 21). Check all other internal joints for leaks.

7.Turn off heater (see To Turn Off Gas to Appliance, page 17 for Thermostat-Controlled models, page 18 for Manually-Controlled Models, or page 20 for Remote-Ready Models).

Equipment

ShutoffOpen

Valve

Closed

Figure 18 - Equipment Shutoff Valve

Equipment

Thermostat Gas

Shutoff Valve

Valve or Control

 

Valve Location

Gas Meter

Figure 20 - Checking Gas Joints (Natural Gas Only)

INSTALLING LOGS

INSTALLING LOGS WARNING: Failure to position the parts in accor- dance with these diagrams or failure to use only parts specifically approved with this heater may result in property damage or personal injury.

Each log is marked with a number. These numbers will help you identify the log when installing. It is very important to install these

Propane/LP Supply Tank

Equipment

 

Shutoff Valve

Thermostat Gas

 

 

Valve or Control

 

Valve Location

logs exactly as instructed. Do not modify logs. Only use logs supplied with heater.

1.Place front log (#1) on top of the grate. Make sure the notches in the bottom of the log fit over the grate prongs (see Figure 21, page 15). Push back of logs flush with metal grate bars.

2.Rest middle log (#2) behind metal posts on grate assembly. Make sure the grooves in the bottom of the log fit over the grate. Bring the log forward next to the metal posts (see Figure 22, page 15).

3.Slide the grooves in the back of the rear log (#3) against the rear grate prongs. Make sure the log fits securely over the prongs (see Figure 23, page 15). Make sure log is completely vertical and not leaning in toward burner where the flame will touch the log.

Figure 19 - Checking Gas Joints (Propane/LP Only)

Manual backgroundManual backgroundManual backgroundManual backgroundManual backgroundForManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background.Manual backgroundManual backgroundManual backgroundManual background.comManual backgroundManual backgroundManual backgroundManual backgroundManual background

110882-01C

Page 14
Image 14
Desa 30, R, V, T installation manual Installation, Continued, Installing Logs, Pressure Testing Heater Gas Connections