OPTIONAL POSITIONING OF THERMOSTAT SENSING BULB
For Masonry and
27
OPTIONAL POSITIONING OF THERMOSTAT SENSING BULB
(Thermostat-Controlled Models Only)
FOR MASONRY AND FACTORY-BUILT METAL FIREPLACE
If your log set cycles to pilot, but the room temperature drops to a lower than ideal comfort level before the log set comes back on, you may want to reposition the thermostat sensing bulb.
The thermostat sensing bulb is located on the gas valve assembly. This location allows the thermostat to keep the room temperature at an ideal comfort level for most fireplace applications. For position- ing the thermostat sensing bulb elsewhere, an
Tools needed: 5/16" hex driver or socket
Capillary
|
| Thermostat |
|
| Sensing |
| Screw | Bulb |
| Retaining Clamp | |
|
| |
Figure 41 - | Figure 42 - Removing | |
Mounting Clip | Thermostat Sensing Bulb |
1. | Locate the gas valve assembly and thermostat sensing bulb |
| (see Figure 40). |
2. | With 5/16" hex driver or socket, loosen the thermostat screw. |
| Carefully slide the thermostat sensing bulb out of the retaining |
| clamp (see Figure 42). |
| Note: Do not remove the screw. Make sure you tighten the |
| screw after removing the thermostat sensing bulb. |
| IMPORTANT: Do not force or bend the thermostat sensing |
| bulb or capillary. |
Thermostat Sensing Bulb
Adhesive- backed Mounting Clip
Thermostat Sensing Bulb
Adhesive- backed Mounting Clip
3. The thermostat sensing bulb may be located to the lower right |
front side of fireplace. Determine location of sensing bulb, but |
do not mount sensing bulb until step 5. If you have a masonry |
fireplace, see Figure 43 for location. |
If you have a |
location. |
Figure 43 - Locating Thermostat | Figure 44 - Locating Thermostat |
Sensing Bulb on Masonry | Sensing Bulb on |
Fireplace | Metal Fireplace |
If your fireplace has glass doors, position sensing bulb directly |
behind door gap on right bottom side (see Figure 45). |
4. The mounting clip must be a minimum of 3" from bottom of |
fireplace to prevent crimping of capillary. Once you have de- |
cided on a location, clean the area thoroughly. Remove the pa- |
per backing from the adhesive on back of mounting clip. Press |
the clip into the new location so that the thermostat sensing bulb |
will be positioned vertically with the capillary at the bottom (see |
Figure 46). Slide the thermostat sensing bulb into the clip. |
IMPORTANT: Do not crimp capillary. |
Thermostat Sensing Bulb
Adhesive- backed Mounting Clip
Glass Doors
Thermostat Sensing Bulb
Adhesive- backed Mounting
Clip
Capillary
Do Not
Crimp Capillary
Gas Valve Assembly
Thermostat
Sensing Bulb
Figure 40 - Location of Gas Valve Assembly and Thermostat Sensing Bulb
Figure 45- Installing Thermostat | Figure 46 - Positioning the |
Sensing Bulb behind Glass | Thermostat Sensing Bulb in |
Doors | the Vertical Position with the |
| Capillary at the Bottom |