Desa 30 Troubleshooting, Continued, Observed Problem, Possible Cause, Remedy, Maintenance, page

Models: R, V, T 30

1 40
Download 40 pages 14.56 Kb
Page 26
Image 26
ing Gas Connections, page 13)

26

TROUBLESHOOTING

TROUBLESHOOTING

Continued

Manual background WARNING: If you smell gas

Shut off gas supply.

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

IMPORTANT: Operating heater where impurities in air exist may create odors. Cleaning supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These fumes may mix with combustion air and create odors. These odors will disappear over time.

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

Remote does not function (Remote-Ready Models Only)

1.Battery is not installed. Battery power is low

1.Replace 9-volt batteries in receiver and hand-held remote

Heater produces a clicking/ticking noise just after burners are lit or shut off

1.Metal expanding while heating or con- tracting while cooling

1.This is common with most heaters. If noise is excessive, contact qualified ser- vice person

Heater produces unwanted odors

1.

Heater burning vapors from paint, hair

 

 

spray, glues, cleaners, chemicals, new

 

 

carpet, etc. (See IMPORTANT state-

 

 

ment above)

 

2.

Low fuel supply (propane/LP only)

 

3.

Gas leak. See Warning statement

 

 

at top of page

1.Open window to ventilate room. Stop us- ing odor causing products while heater is running

2.Refill supply tank (propane/LP only)

3.Locate and correct all leaks (see Check- ing Gas Connections, page 13)

Heater shuts off in use (ODS operates)

1.

Not enough fresh air is available

1.

Open window and/or door for ventilation

 

2.

Low line pressure

2.

Contact local natural or propane/LP gas

 

 

 

 

company

 

3.

ODS/pilot is partially clogged

3.

Clean ODS/pilot (see Cleaning and

 

 

 

 

Maintenance, page 23)

 

 

 

 

 

Gas odor even when control knob is in OFF

1.

Gas leak. See Warning statement

1.

Locate and correct all leaks (see Check-

position

 

at top of page

 

ing Gas Connections, page 13)

 

2.

Control valve or gas control defective

2.

Replace control valve or gas control

 

 

 

 

 

Gas odor during combustion

1.

Foreign matter between control valve

 

 

and burner

 

2.

Gas leak. See Warning statement

 

 

at top of page

1.Take apart gas tubing and remove for- eign matter

2.Locate and correct all leaks (see Check- ing Gas Connections, page 13)

Log set cycles to pilot, but room tempera- ture drops to a lower than ideal level before log set comes back on

1.Thermostat sensing bulb needs to be repositioned (Thermostat-Controlled Models Only)

2.Hand-held remote control is too close to heater (Remote-Ready Models Only)

1.Reposition thermostat sensing bulb (see Instructions for Optional Positioning of Thermostat Sensing Bulb, page 27)

2.Move hand-held remote control unit far- ther away from the heater

Manual backgroundManual backgroundManual backgroundManual backgroundManual backgroundForManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background.Manual backgroundManual backgroundManual backgroundManual background.comManual backgroundManual backgroundManual backgroundManual backgroundManual background

110882-01C

Page 26
Image 26
Desa 30 Troubleshooting, Continued, Observed Problem, Possible Cause, Remedy, Maintenance, page, ing Gas Connections, page