Grizzly H8117 owner manual Troubleshooting, Symptom Possible Cause Solution

Page 17

Troubleshooting

Symptom

Possible Cause

Solution

 

 

 

 

 

 

 

 

 

Fluttering or

1. Dry or worn fluid tip seat per-

1.

Tighten fluid tip or replace

Spitting spray.

 

mits air to seep into fluid pas-

 

seat with new one.

 

 

 

 

 

 

 

sage.

 

 

 

 

 

 

 

 

2.

Material level too low.

2.

Add material.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3.

Fluid tip or filter obstructed.

3.

Clean

 

 

 

 

 

 

4.

Dry needle packing.

4.

Lubricate needle.

 

 

 

 

 

 

 

 

 

Uneven top

 

or

bot-

1. Atomizing cap holes are

1.

Clear holes.

tom

pattern.

 

 

 

 

obstructed.

 

 

 

 

 

 

 

 

2.

Build-up on top or bottom of

2.

Clean.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

fluid tip.

 

 

 

 

 

 

 

 

3.

Build-up on atomizing cap is

3.

Clean.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

on needle seat.

 

 

 

 

 

 

 

 

 

 

 

Right or left arc

1. Left or right side horn holes

1.

Clear holes.

pattern.

 

are plugged.

 

 

 

 

 

 

 

 

2.

Build-up on left or right side of

2.

Clean.

 

 

 

 

 

 

 

fluid tip.

 

 

 

 

 

 

 

 

3.

Build-up of material inside

3. Clean.

 

 

 

 

 

 

 

atomizing cap.

 

 

 

 

 

 

 

 

 

 

 

Heavy deposit of

1. The material flow exceeds the

1.

Lower fluid flow.

material in center.

 

atomizing cap capacity.

 

 

 

 

 

 

 

 

2.

Inlet air pressure is too low.

2.

Increase inlet air pressure.

 

 

 

 

 

 

3.

Material is too thick.

3.

Thin material.

 

 

 

 

 

 

 

 

 

Narrow center pat-

1. Volume control turned in too

1.

Increase volume.

tern.

 

far.

 

 

 

 

 

 

 

 

2.

Inlet air pressure too high.

2.

Reduce inlet air pressure.

 

 

 

 

 

 

3.

Fluid pressure is too low.

3.

Increase fluid pressure.

 

 

 

 

 

 

4.

Material is too thin.

4.

Adjust material.

 

 

 

 

 

 

 

 

 

No spray output.

1. No pressure at gun.

1.

Check air supply.

 

 

 

 

 

 

2.

Fluid passages dirty.

2.

Clean gun, remove any

 

 

 

 

 

 

 

 

 

obstructions.

 

 

 

 

 

 

3.

Fluid control closed.

3.

Open.

 

 

 

 

 

 

4.

Out of paint.

4.

Refill.

 

 

 

 

 

 

 

 

 

 

Model H8115/H8117 Spray Gun

-17-

Image 17
Contents Mini Spray GUN Page Table of Contents Before Operating this Equipment SafetySafety Instructions for Pneumatic Tools Wear Approved Hearing Protection Operating PRESSURE. do Additional Safety Instructions for Spray GunsForeword Contact Info IntroductionTool Data Sheet H8115 Assembly SET UPH8117 Assembly UnpackingControls Spraying OperationsModel H8115/H8117 Spray Gun Set up for horizontal stroke Atomizing Cap Fan AdjustmentsG6261-Campbell Hausfeld Water Filter AccessoriesCleaning MaintenanceLubrication points, Model H8115 LubricationSymptom Possible Cause Solution TroubleshootingSymptom Possible Cause Solution Model H8115/H8117 Spray Gun REF Description Parts Breakdown H8115Parts Breakdown H8117 Warranty and Returns Warranty Card Place Stamp Here