Carrier 48TF004-007 specifications 48TF006 5 Tons HIGH-STATIC Motor Belt Drive

Page 25

Table 16 — Fan Performance 48TF006 — Vertical Discharge Units, High-Static Motor

48TF006 (5 TONS) — HIGH-STATIC MOTOR (BELT DRIVE)*

Airflow

 

 

 

 

 

External Static Pressure (in. wg)

 

 

 

 

 

 

 

 

0.2

 

 

0.4

 

 

0.6

 

 

0.8

 

 

1.0

 

 

(Cfm)

 

 

 

 

 

 

 

 

 

 

 

 

Rpm

Bhp

Watts

Rpm

Bhp

Watts

Rpm

Bhp

Watts

Rpm

Bhp

Watts

Rpm

 

Bhp

 

Watts

1500

808

0.42

429

914

0.56

572

1001

0.69

705

1084

0.85

869

1168

 

1.01

 

1032

1600

846

0.49

501

950

0.64

645

1034

0.78

797

1111

0.94

961

1194

 

1.11

 

1134

1700

884

0.57

592

983

0.72

736

1068

0.88

899

1145

1.03

1053

1218

 

1.21

 

1237

1800

942

0.66

674

1018

0.82

838

1105

0.98

1001

1179

1.13

1155

1246

 

1.32

 

1349

1900

965

0.78

777

1057

0.92

940

1143

1.10

1124

1212

1.26

1288

1280

 

1.43

 

1481

2000

1008

0.87

889

1096

1.04

1063

1177

1.22

1247

1247

1.40

1431

1300

 

1.57

 

1604

2100

1051

0.99

1012

1136

1.17

1196

1210

1.35

1380

1284

1.54

1574

1347

 

1.72

 

1758

2200

1095

1.12

1145

1173

1.30

1328

1245

1.49

1523

1322

1.70

1737

1380

 

1.89

 

1931

2300

1140

1.28

1288

1210

1.47

1502

1284

1.65

1686

1356

1.80

1901

1418

 

2.07

 

2115

2400

1185

1.41

1441

1249

1.61

1645

1323

1.80

1860

1389

2.03

2074

1456

 

2.26

 

2310

2500

1231

1.57

1604

1289

1.78

1819

1363

2.00

2044

1424

2.22

2269

1500

 

2.45

 

2504

 

 

 

 

 

 

 

 

 

 

 

 

48TF006 (5 TONS) — HIGH-STATIC MOTOR (BELT DRIVE)* (cont)

 

 

 

 

 

 

 

 

 

 

 

Airflow

 

 

 

 

 

External Static Pressure (in. wg)

 

 

 

 

 

 

 

 

1.2

 

 

1.4

 

 

1.6

 

 

1.8

 

 

2.0

 

 

(Cfm)

 

 

 

 

 

 

 

 

 

 

 

 

Rpm

Bhp

Watts

Rpm

Bhp

Watts

Rpm

Bhp

Watts

Rpm

Bhp

Watts

Rpm

 

Bhp

 

Watts

1500

1199

1.19

1216

1126

1.46

1492

1250

1.69

1757

1301

1.91

1944

1349

 

2.12

 

2164

1600

1263

1.28

1308

1275

1.49

1523

1299

1.78

1800

1352

2.01

2047

1401

 

2.23

 

2280

1700

1295

1.39

1420

1351

1.58

1615

1352

1.80

1850

1407

2.03

2070

1459

 

2.26

 

2305

1800

1319

1.52

1553

1389

1.71

1747

1453

1.91

1952

1494

2.15

2197

1548

 

2.40

 

2446

1900

1343

1.64

1676

1415

1.80

1891

1478

2.05

1095

1538

2.31

2358

1594

 

2.57

 

2625

2000

1374

1.77

1809

1438

1.99

2034

1505

2.21

2258

1566

2.49

2542

1624

 

2.77

 

2830

2100

1409

1.91

1952

1465

2.14

2167

1533

2.45

2501

1596

2.77

2821

1654

 

3.08

 

3141

2200

1442

2.08

2126

1498

2.30

2350

1568

2.64

2688

1632

2.97

3031

1691

 

3.31

 

3375

2300

1475

2.26

2310

1554

2.64

2698

 

 

 

1693

3.42

3486

1755

 

3.81

 

3881

1627

3.03

3091

 

 

2400

1565

2.47

2524

1649

2.89

2948

1726

3.31

3379

 

2500

 

 

 

 

 

 

1760

3.96

4036

 

1596

2.95

3010

1682

3.45

3522

LEGEND

Bhp — Brake Horsepower Input to Fan

FIOP — Factory-Installed Option

Watts — Input Watts to Motor

*Motor drive range is 1300 to 1685 rpm. All other rpms require a field- supplied drive.

NOTES:

1.Boldface indicates field-supplied drive is required.

2. indicates field-supplied motor and drive are required.

3.Values include losses for filters, unit casing, and wet coils. See Table 7 for accessory/FIOP static pressure information.

4.Maximum continuous bhp is 2.9 and the maximum continuous watts are 2562. Extensive motor and electrical testing on these units ensures that the full range of the motor can be utilized with confidence. Using your fan motors up to the wattage ratings shown will not result in nuisance tripping or premature motor failure. Unit warranty will not be affected. See Table 6 — Motor Data for addi- tional information.

5.Use of a field-supplied motor may affect wire sizing. Contact your Carrier representative for details.

6.Interpolation is permissible. Do not extrapolate.

25

Image 25
Contents Installation, Start-Up, Service Instructions Rig and Place Unit Inspect unit for Field Fabricate Ductwork Secure allRoof Curb Dimensions Install Gas Piping Unit is equipped for Install Flue Hood Flue hood is shippedUnit Size 48TF Physical Data 48TF004-007Furnace Section Base Unit Dimensions Steel Pipe Nominal Diameter Make Electrical ConnectionsFeet Or largerAHA Terminal BlockSupply Size Electrical DataType FLA RLA LRAPosition Setting Make Outdoor-Air Adjustments and Install Outdoor-Air HoodTypical Access Panel Locations Horizontal Discharge Block-Off Plate Wiring Connections for Outdoor-Air Thermostat Completed Hood Assembly EconoMi$er Wiring Wiring Diagram for Power Exhaust System Settings Default Potentiometer Settin gsPotentiometer Default Setting CO2 SP PPM Chan geover Set PointsDirect Drive Motor Mounting Adjust Evaporator-Fan Speed AdAccessory/FIOP Static Pressure* in. wg 48TF004-007 Fan Rpm at Motor Pulley SettingsMotor Data 48TF004 3 Tons Alternate Motor Belt Drive 48TF004 3 Tons Standard Motor Direct Drive48TF005 4 Tons Standard Motor Direct Drive 48TF004 3 Tons HIGH-STATIC Motor Belt Drive48TF005 4 Tons Alternate Motor Belt Drive 48TF006 5 Tons Alternate Motor Belt Drive 48TF006 5 Tons Standard Motor Direct Drive48TF006 5 Tons HIGH-STATIC Motor Belt Drive 48TF007 6 Tons Standard Motor Belt Drive 48TF007 6 Tons HIGH-STATIC Motor Belt Drive 149 109189 2291064 10281005 93848TF005 4 Tons Alternate Motor Belt Drive 48TF005 4 Tons HIGH-STATIC Motor Belt Drive 1700 811 494 865 567 1600 770 420 826 4831800 852 578 1900 894 5671600 826 483 931 641 1020 788 1101 956 1178 12211252 1700 865 567 966 725 1051 883 1133 1061 1205928 700 982 779 885 623 942 700971 787 1022 867 1015 891 1063 9982000 1022 867 1121 1014 1188 1097 1254 1216 1900 982 779 1084 932 1160 1006 1223 11142100 1063 998 1140 1064 1196 1272 1292 2200 1104 1081 1159 1106 1229 1258Altitude Compensation HeatingBtuh Nominal Nominal InputPage Service Lubrication Economizer Adjustment Refer to Optional EconoTON Unit Charging Chart TON Unit 60 Hz Charging Chart Cooling Charging Chart, 48TF006LED Indication Error Code Description LED Error Code DescriptionOFF FlashesBurner Tray Details Heating Service Analysis LED Error Code Service AnalysisProblem Cause Remedy LED OFFCooling Service Analysis IFC Durablade Economizer TroubleshootingEconoMi$er Troubleshooting Typical Wiring Diagram and Component Arrangement CAP SATSEN SW1Copyright 2000 Carrier Corporation Page Preliminary Information Remove and Use in Job File

48TF004-007 specifications

The Carrier 48TF004-007 is part of the brand's renowned rooftop unit series, designed to deliver efficient, reliable performance for commercial applications. Ideal for spaces such as offices, retail stores, and small manufacturing facilities, these units encapsulate advanced technology to enhance indoor air quality and optimize climate control.

One of the standout features of the Carrier 48TF004-007 units is their variable speed compressor technology. This innovation not only allows for precise temperature control but also reduces energy consumption by modulating the compressor's speed according to the cooling or heating demand. By operating at lower speeds during less demanding conditions, these units significantly decrease energy usage compared to traditional single-speed compressors, contributing to lower utility bills and a reduced carbon footprint.

Energy efficiency is further enhanced with the inclusion of high-performance scroll compressors, which are known for their reliable operation and quiet performance. Coupled with an Energy Efficiency Ratio (EER) that meets or exceeds industry standards, these systems are designed to offer economical operation without sacrificing comfort.

Incorporating smart controls and connectivity features, the Carrier 48TF004-007 units allow for easy integration into building management systems (BMS). This enhances the ability to monitor and manage energy usage in real time, further promoting efficiency. The units are also compatible with various thermostat options, allowing for user-friendly operation and customization of settings.

Another significant characteristic of the Carrier 48TF004-007 is its durable construction. Built with galvanized steel and powder-coated finishes, these units are designed to withstand the rigors of outdoor installation, ensuring long-lasting performance even in harsh weather conditions. Additionally, the units come equipped with advanced filtration systems that help improve indoor air quality by effectively removing dust, allergens, and other particulate matter from the air.

Maintenance is simplified with the Carrier 48TF004-007, providing easy access to vital components, which supports reduced downtime and service costs. The units also feature low operating sound levels, making them suitable for noise-sensitive applications.

In conclusion, the Carrier 48TF004-007 rooftop units stand out for their energy efficiency, advanced technology, durability, and ease of maintenance, making them an excellent choice for any commercial space looking to enhance comfort while effectively managing operational costs.