Carrier 48TF004-007 specifications Furnace Section

Page 6

Table 1 — Physical Data — 48TF004-007 (cont)

UNIT SIZE 48TF

 

 

E/F/M/N004

D/E/F/L/M/N005

 

D/E/F/L/M/N006

D/E/F007

FURNACE SECTION

 

 

 

 

 

 

 

Rollout Switch Cutout

 

 

 

 

 

 

 

Temp (F)††

 

 

195

195

 

195

195

Burner Orifice Diameter

 

 

 

 

 

 

(in. ...drill size)

 

 

 

 

 

 

 

Natural Gas

Std

TFD

.113...33

 

.113...33

.113...33

 

 

TFE

.113...33

.113...33

 

.113...33

.113...33

 

 

TFF

.113...33

.129...30

 

.129...30

.129...30

 

 

TFL

.102...38

 

.102...38

 

 

TFM

.102...38

.102...38

 

.102...38

 

 

TFN

.102...38

.116...32

 

.116...32

Liquid Propane

Alt

TFD

.089...43

 

.089...43

.089...43

 

 

TFE

.089...43

.089...43

 

.089...43

.089...43

 

 

TFF

.089...43

.102...38

 

.102...38

.102...38

 

 

TFL

.082...45

 

.082...45

 

 

TFM

.082...45

.082...45

 

.082...45

Thermostat Heat Anticipator

TFN

.082...45

.089...43

 

.089...43

 

 

 

 

 

 

Setting (amps)

 

 

 

 

 

 

 

208/230 v and 575

Stage 1

 

.14

.14

 

.14

.14

 

Stage 2

 

.14

.14

 

.14

.14

460 v

Stage 1

 

.14

.14

 

.14

.14

 

Stage 2

 

.14

.14

 

.14

.14

Gas Input (Btuh)

Stage 1

TFD

72,000

 

72,000

72,000

 

 

TFE

72,000

115,000

 

115,000

115,000

 

 

TFF

82,000

120,000

 

120,000

120,000

 

 

TFL

60,000

 

60,000

 

 

TFM

60,000

90,000

 

90,000

 

 

TFN

90,000

120,000

 

120,000

 

Stage 2

TFF

115,000

150,000

 

150,000

150,000

 

(3-phase units)

 

Efficiency (Steady

 

 

 

 

 

 

 

 

 

 

 

 

 

State) (%)

 

 

80

80

 

80

80

Temperature Rise Range

TFD

25-55

 

25-55

25-55

 

 

TFE

25-55

35-65

 

35-65

35-65

 

 

TFF

55-85

50-80

 

50-80

50-80

 

 

TFL

20-50

 

20-50

 

 

TFM

20-50

30-60

 

30-60

Manifold Pressure (in. wg)

TFN

30-60

40-70

 

40-70

 

 

 

 

 

 

Natural Gas

Std

 

3.5

3.5

 

3.5

3.5

Liquid Propane

Alt

 

3.5

3.5

 

3.5

3.5

Gas Valve Quantity

 

 

1

1

 

1

1

Gas Valve Pressure Range

 

 

 

 

 

 

Psig

 

 

0.180-0.487

0.180-0.487

 

0.180-0.487

0.180-0.487

in. wg

 

 

5.0-13.5

5.0-13.5

 

5.0-13.5

5.0-13.5

Field Gas Connection

 

 

1/

1/

 

1/

1/

Size (in.)

 

 

 

 

 

 

2

2

 

2

2

HIGH-PRESSURE SWITCH (psig)

 

 

 

 

 

 

Standard Compressor

 

 

 

450 ± 50

 

 

500 ± 50

Internal Relief (Differential)

 

 

 

 

 

 

Cutout

 

 

 

428

 

 

428

Reset (Auto.)

 

 

 

320

 

 

320

LOSS-OF-CHARGE (LOW-

 

 

 

7 ± 3

 

PRESSURE SWITCH) (psig)

 

 

 

 

Cutout

 

 

 

 

 

 

 

Reset (Auto.)

 

 

 

 

22 ± 7

 

FREEZE PROTECTION

 

 

 

 

 

 

 

THERMOSTAT (F)

 

 

 

 

 

 

 

Opens

 

 

 

 

30 ± 5

 

Closes

 

 

 

 

45 ± 5

 

OUTDOOR-AIR INLET SCREENS

 

 

 

Cleanable

 

Quantity...Size (in.)

 

 

 

1...20 x 24 x 1

 

RETURN-AIR FILTERS

 

 

 

Throwaway

 

Quantity...Size (in.)

 

 

 

2...16 x 25 x 2

 

 

 

LEGEND

Al

Aluminum

Bhp

Brake Horsepower

Cu

Copper

*Evaporator coil fin material/condenser coil fin material. Contact your local representative for details about coated fins.

†Weight of 14-in. roof curb. **Single phase/three-phase.

††Rollout switch lockout is manually reset by interrupting power to unit or resetting thermostat.

Single-phase units have a single-stage gas valve. The heating input values are as follows:

48TFF004, 115,000 Btuh 48TFF005, 150,000 Btuh 48TFF006, 150,000 Btuh

NOTE: High-static motor not available on single-phase units.

6

Image 6
Contents Installation, Start-Up, Service Instructions Field Fabricate Ductwork Secure all Rig and Place Unit Inspect unit forRoof Curb Dimensions Install Flue Hood Flue hood is shipped Install Gas Piping Unit is equipped forPhysical Data 48TF004-007 Unit Size 48TFFurnace Section Base Unit Dimensions Feet Make Electrical ConnectionsSteel Pipe Nominal Diameter Or largerTerminal Block AHAType FLA Electrical DataSupply Size RLA LRAMake Outdoor-Air Adjustments and Install Outdoor-Air Hood Position SettingTypical Access Panel Locations Horizontal Discharge Block-Off Plate Wiring Connections for Outdoor-Air Thermostat Completed Hood Assembly EconoMi$er Wiring Wiring Diagram for Power Exhaust System Potentiometer Default Setting CO2 SP PPM Default Potentiometer Settin gsSettings Chan geover Set PointsAdjust Evaporator-Fan Speed Ad Direct Drive Motor MountingFan Rpm at Motor Pulley Settings Accessory/FIOP Static Pressure* in. wg 48TF004-007Motor Data 48TF004 3 Tons Standard Motor Direct Drive 48TF004 3 Tons Alternate Motor Belt Drive48TF004 3 Tons HIGH-STATIC Motor Belt Drive 48TF005 4 Tons Standard Motor Direct Drive48TF005 4 Tons Alternate Motor Belt Drive 48TF006 5 Tons Standard Motor Direct Drive 48TF006 5 Tons Alternate Motor Belt Drive48TF006 5 Tons HIGH-STATIC Motor Belt Drive 48TF007 6 Tons Standard Motor Belt Drive 48TF007 6 Tons HIGH-STATIC Motor Belt Drive 189 109149 2291005 10281064 93848TF005 4 Tons Alternate Motor Belt Drive 48TF005 4 Tons HIGH-STATIC Motor Belt Drive 1800 852 578 1600 770 420 826 4831700 811 494 865 567 1900 894 5671252 12211600 826 483 931 641 1020 788 1101 956 1178 1700 865 567 966 725 1051 883 1133 1061 1205971 787 1022 867 885 623 942 700928 700 982 779 1015 891 1063 9982100 1063 998 1140 1064 1196 1272 1292 1900 982 779 1084 932 1160 1006 1223 11142000 1022 867 1121 1014 1188 1097 1254 1216 2200 1104 1081 1159 1106 1229 1258Btuh Nominal HeatingAltitude Compensation Nominal InputPage Service Economizer Adjustment Refer to Optional Econo LubricationTON Unit Charging Chart Cooling Charging Chart, 48TF006 TON Unit 60 Hz Charging ChartOFF LED Error Code DescriptionLED Indication Error Code Description FlashesBurner Tray Details Problem Cause Remedy LED Error Code Service AnalysisHeating Service Analysis LED OFFCooling Service Analysis Durablade Economizer Troubleshooting IFCEconoMi$er Troubleshooting Typical Wiring Diagram and Component Arrangement SEN SATCAP SW1Copyright 2000 Carrier Corporation Page Remove and Use in Job File Preliminary Information

48TF004-007 specifications

The Carrier 48TF004-007 is part of the brand's renowned rooftop unit series, designed to deliver efficient, reliable performance for commercial applications. Ideal for spaces such as offices, retail stores, and small manufacturing facilities, these units encapsulate advanced technology to enhance indoor air quality and optimize climate control.

One of the standout features of the Carrier 48TF004-007 units is their variable speed compressor technology. This innovation not only allows for precise temperature control but also reduces energy consumption by modulating the compressor's speed according to the cooling or heating demand. By operating at lower speeds during less demanding conditions, these units significantly decrease energy usage compared to traditional single-speed compressors, contributing to lower utility bills and a reduced carbon footprint.

Energy efficiency is further enhanced with the inclusion of high-performance scroll compressors, which are known for their reliable operation and quiet performance. Coupled with an Energy Efficiency Ratio (EER) that meets or exceeds industry standards, these systems are designed to offer economical operation without sacrificing comfort.

Incorporating smart controls and connectivity features, the Carrier 48TF004-007 units allow for easy integration into building management systems (BMS). This enhances the ability to monitor and manage energy usage in real time, further promoting efficiency. The units are also compatible with various thermostat options, allowing for user-friendly operation and customization of settings.

Another significant characteristic of the Carrier 48TF004-007 is its durable construction. Built with galvanized steel and powder-coated finishes, these units are designed to withstand the rigors of outdoor installation, ensuring long-lasting performance even in harsh weather conditions. Additionally, the units come equipped with advanced filtration systems that help improve indoor air quality by effectively removing dust, allergens, and other particulate matter from the air.

Maintenance is simplified with the Carrier 48TF004-007, providing easy access to vital components, which supports reduced downtime and service costs. The units also feature low operating sound levels, making them suitable for noise-sensitive applications.

In conclusion, the Carrier 48TF004-007 rooftop units stand out for their energy efficiency, advanced technology, durability, and ease of maintenance, making them an excellent choice for any commercial space looking to enhance comfort while effectively managing operational costs.