Senco PC2016 operating instructions Insufficient pressure at air tool or accessory

Page 14

TROUBLESHOOTING

SYMPTOM

11.Insufficient pressure at air tool or accessory.

 

 

PROBABLE CAUSE

REMEDY

Pressure regulator knob not turned to high enough

Adjust pressure regulator knob to proper setting or

pressure or defective pressure regulator.

replace.

Restricted air intake filter.

Clean or replace.

Air leaks.

Check for leaks and repair.

Hose or hose connections are too small or long.

Replace with larger hose or connectors.

Slipping belt.

Tighten or replace.

Air compressor is not large enough for air require-

Check the accessory air requirement. If it is higher

ment.

than the CFM or pressure supply of the air

 

compressor, you need a larger air compressor.

SYMPTOM

12.Air compressor not making enough air.

PROBABLE CAUSE

REMEDY

Restricted air intake filter.

Clean or replace.

Defective (reed) valve.

Drain air tank and measure pump up time. Compare

to specifications. If longer, remove pump head and

 

inspect valve plate, clean or replace.

Restriction in pilot valve.

Clean or replace.

SYMPTOM

13.Excessive oil consumption in pump.

PROBABLE CAUSE

REMEDY

Restricted air intake filter.

Clean or replace.

Air compressor on unlevel surface.

Do not incline the air compressor more than 10° in

 

any direction while running.

Crankcase overfilled with oil.

Drain oil. Refill to proper level with Senco PC0344

 

oil.

Plugged oil dipstick vent.

Clean.

Oil leaks.

Repair.

Worn piston rings or scored cylinder.

Contact Senco Customer Service 800-543-4596.

SYMPTOM

14. Oil has milky appearance.

PROBABLE CAUSE

REMEDY

Water in oil due to condensation.

Change oil and move air compressor to a less humid

 

environment.

SYMPTOM

15. Moisture in discharge air.

PROBABLE CAUSE

REMEDY

Condensation in air tank caused by high level of at-

Drain air tank after every use. Drain air tank more

mospheric humidity or air compressor is not run long

often in humid weather and use an air line filter.

enough.

 

14

Senco® Electric Air Compressor Manual 2004

Image 14
Contents PC2016 Electric Air Compressor Table of Contents Inspection Safety AlertIntroduction Electric Shock Safety WarningsHazard Potential Consequence Prevention Risk ElectrocutionExplosion or Fire BurstingBurns Hazard Potential Consequence Prevention Risk toBreathing Flying ObjectsNegligence Potential Consequence Prevention Hazard Risk fromMoving Parts AIR CompressorPC2016 Electric AIR Compressor Features PC2016 Features Review Location PreparationInitial SET-UP ElectricalOperation MaintenancePRE-START Checklist ShutdownTroubleshooting Probable Cause RemedyProbable Cause Insufficient pressure at air tool or accessory Specifications Senco Compressor and Parts Warranty Compressor Warranty