Carrier 50TC installation instructions

Page 2

50TC

!WARNING

ELECTRICAL SHOCK HAZARD

Failure to follow this warning could cause personal injury or death.

Before performing service or maintenance operations on unit, always turn off main power switch to unit and install lockout tag. Unit may have more than one power switch.

!WARNING

UNIT OPERATION AND SAFETY HAZARD

Failure to follow this warning could cause personal injury, death and/or equipment damage.

Puronr (R-410A) refrigerant systems operate at higher pressures than standard R-22 systems. Do not use R-22 service equipment or components on Puron refrigerant equipment.

!WARNING

PERSONAL INJURY AND ENVIRONMENTAL HAZARD

Failure to follow this warning could cause personal injury or death.

Relieve pressure and recover all refrigerant before system repair or final unit disposal.

Wear safety glasses and gloves when handling refrigerants. Keep torches and other ignition sources away from refrigerants and oils.

!CAUTION

CUT HAZARD

Failure to follow this caution may result in personal injury.

Sheet metal parts may have sharp edges or burrs. Use care and wear appropriate protective clothing, safety glasses and gloves when handling parts and servicing furnaces.

2

Image 2
Contents Installation Instructions 50TC Unit Dimensional Drawing 07 Size Units Unit Dimensional Drawing 07 Size Unit Unit Dimensional Drawing 08, 09 and 12 Size Units Plan for Unit Location Roof mountProvide Unit Support Plan for Sequence of Unit InstallationInspect unit Roof Curb Details 07 Size Units Roof Curb Details 08 12 Size Units Field Fabricate Ductwork Unit Leveling TolerancesEconomizer Hood Removal and Setup Factory Option Convert to Horizontal and Connect Ductwork when requiredInstall Outside Air Hood Rig and Place UnitEconomizer Hood and Two-Position Hood Two Position Damper Hood Removal and SetupFactory Option Install External Condensate Trap and Line Make Electrical ConnectionsThru-Base Connections Units with Factory-Installed DisconnectAll units Units without Thru-Base Connections Field Control WiringHeat Anticipator Settings ThermostatElectric Heaters Heater Model NumberAccessory Electric Heater Control Connections PremierLinkt Factory-Option PremierLink ControllerPremierLink Wiring Schematic PremierLink Sensor Usage 33ZCT55SPT CRTEMPSN001A00Space Sensor Mode Thermostat Mode55 Space Temperature Sensor Wiring Enthalpy Switch HH57AC077 Connections Economizer controlsIndoor CO2 Sensor 33ZCSENCO2 Connections PremierLink Filter Switch Connection PremierLink Wiring Fan Pressure Switch ConnectionColor Code Recommendations PremierLink CCN Bus ConnectionsRTU-MP control system RTU-MP Multi-Protocol Control BoardRTU-MP System Control Wiring Diagram RTU-MP Controller Inputs and Outputs Type of I/O Connection PIN Name Numbers InputsSpace Temperature SPT Sensors RTU-MP T-55 Sensor ConnectionsConnecting Discrete Inputs Filter Status RTU-MP / Indoor CO2 Sensor 33ZCSENCO2 ConnectionsRemote Occupancy Communication Wiring Protocols GeneralFan Status Local Access RTU-MP Troubleshooting Communication LEDsLEDs LEDs on the RTU-MP show the status of certain functionsEconoMi$er IV Occupancy Switch Adjust Factory-Installed OptionsInstall Accessories Pre-Start and Start-UpUnit Wire/MOCP Sizing Data STD17.5 108 Disc 50TC Catalog No 50TC---C02SI

50TC specifications

The Carrier 50TC is a cutting-edge commercial rooftop unit designed for optimal performance and reliability in a variety of HVAC applications. This unit is particularly well-suited for small to medium-sized facilities that require efficient heating, ventilation, and air conditioning solutions. A hallmark of the Carrier 50TC is its impressive energy efficiency, enabling users to significantly lower their operational costs while maintaining a comfortable indoor environment.

One of the standout features of the Carrier 50TC is its advanced performance technologies. The unit employs a high-efficiency scroll compressor that enhances refrigerant management, allowing for exceptional cooling capacities while minimizing energy consumption. Additionally, the unit is equipped with variable speed fans, which further contribute to its operational efficiency. These fans adjust their speed according to the cooling demands, allowing the system to consume energy only when necessary.

The Carrier 50TC also incorporates an innovative control system that provides intelligent diagnostics and an array of customizable settings. This system helps in monitoring the unit's performance, ensuring maximum efficiency and early detection of potential maintenance issues. Users can easily integrate the unit within their existing building management systems, enhancing overall operational control and streamlining HVAC management procedures.

Durability and ease of maintenance are key characteristics of the Carrier 50TC, designed specifically to withstand harsh weather conditions while providing long-lasting performance. The unit's robust construction includes a powder-coated cabinet, which not only improves its aesthetic appeal but also protects against corrosion, ensuring longevity.

Moreover, the Carrier 50TC is designed with eco-friendliness in mind. It utilizes environmentally friendly refrigerants, aligning with modern regulations aimed at reducing the impact of HVAC systems on the environment. By choosing the Carrier 50TC, businesses can contribute to sustainability efforts while enjoying effective temperature control.

In summary, the Carrier 50TC combines energy efficiency, advanced technologies, and robust design to deliver a reliable HVAC solution for commercial applications. With its smart control system, high-efficiency components, and eco-friendly operation, the Carrier 50TC sets a standard for performance and sustainability in the commercial heating and cooling market.