Carrier 50RHE006-060 specifications Left Return, Right Return

Page 4

 

 

 

 

 

 

 

WATER

 

ELECTRICAL KNOCKOUTS (in.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OVERALL

 

CONNECTIONS

 

DISCHARGE CONNECTION

 

RETURN CONNECTION

 

 

 

 

 

 

 

 

 

50RHE

 

CABINET

1

2

3

Loop

J

K

L

 

Duct Flange Installed (±0.10 in.)

 

Using Return Air Opening

 

 

 

 

1/2 conduit

1/2 conduit

3/4 conduit

 

 

 

 

 

 

 

 

 

 

 

UNITS

 

 

 

 

 

 

 

Water

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A

 

B

C

D

E

F

FPT

Low

Ext

Power

 

 

L

M

 

 

 

P

Q

 

 

 

 

 

Cond-

(in.)

J

K

Supply

Supply

N

 

O

Return

Return

R

S

 

 

Width

 

Depth

Height

In

Out

Voltage

Pump

Supply

 

 

 

 

ensate

 

 

 

Height

Depth

 

 

 

Depth

Height

 

 

006-012

in.

22.4

 

43.1

11.3

2.4

5.4

0.6

1/2

3.5

5.5

8.2

5.8

4.0

5.8

8.0

5.8

 

1.5

17.1

9.3

2.2

1.0

cm

56.8

 

109.5

28.7

6.1

13.7

1.5

8.9

14.0

20.8

14.7

10.2

14.7

20.3

14.7

 

3.8

43.4

23.6

5.6

2.5

015-024

in.

22.4

 

43.1

17.3

2.4

4.9

0.6

3/4

3.5

7.5

10.2

5.0

5.6

10.4

9.3

5.0

 

1.5

17.1

15.3

2.2

1.0

cm

56.8

 

109.5

43.9

6.1

12.4

1.5

8.9

19.1

25.9

12.7

14.2

26.4

23.6

12.7

 

3.8

43.4

38.9

5.6

2.5

030

in.

22.4

 

53.2

19.3

2.4

5.4

0.6

3/4

5.7

9.7

12.2

5.0

6.8

10.4

9.3

5.0

 

2.1

23.1

17.3

2.2

1.0

cm

56.8

 

135.1

49.0

6.1

13.7

1.5

14.5

24.6

31.0

12.7

17.3

26.4

23.6

12.7

 

5.3

58.7

43.9

5.6

2.5

 

 

 

 

036

in.

22.4

 

53.2

19.3

2.4

5.4

0.6

3/4

5.7

9.7

12.2

2.9

3.8

13.5

13.1

2.9

 

1.9

23.1

17.3

2.2

1.0

cm

56.8

 

135.1

49.0

6.1

13.7

1.5

14.5

24.6

31.0

7.4

9.7

34.3

33.3

7.4

 

4.8

58.7

43.9

5.6

2.5

 

 

 

 

042-048

in.

22.4

 

62.2

19.3

2.4

5.4

0.6

1

5.7

9.7

12.2

2.9

3.8

13.5

13.1

2.9

 

1.9

32.1

17.3

2.2

1.0

cm

56.8

 

158.0

49.0

6.1

13.7

1.5

14.5

24.6

31.0

7.4

9.7

34.3

33.3

7.4

 

4.8

81.5

43.9

5.6

2.5

060

in.

25.4

 

71.2

21.3

2.4

5.4

0.6

1

8.1

11.7

14.2

5.8

5.0

13.6

13.3

5.8

 

2.9

36.1

19.3

2.2

1.0

cm

64.5

 

180.8

54.1

6.1

13.7

1.5

20.6

29.7

36.1

14.7

12.7

34.5

33.8

14.7

 

7.4

91.7

49.0

5.6

2.5

 

 

 

 

NOTES:

1.Condensate is 3/4-in. FPT copper.

2.Horizontal unit shipped with filter bracket only. This bracket should be removed for return duct connection (front).

3.Hanger kit is factory installed. Isolation grommets are provided.

4.Right and left orientation is determined by looking at water connection side.

 

 

LEFT RETURN

2’ [61cm]

 

CSP Optional 2’ [61cm]

Service

Front

Service Access *

Access *

 

 

Left Return

Legend

CAP=Control Access Panel

CSP=Compressor Service Panel

BSP=Blower Service Panel

ASP=Alternate Service Panel

Power Supply

3 / 4” Knockout

RIGHT RETURN

Front

2’ [61cm] Service

Access *

 

Optional 2’ [61cm]

Service Access *

Right Return

ASP

 

 

 

1 / 2”

 

 

3.25

Knockout

 

 

 

 

 

 

 

 

 

 

[82.6mm]

 

 

 

 

Low Voltage

 

 

 

 

1 / 2” Knockout

 

Right

 

F

 

 

 

5

 

 

Discharge

 

 

 

 

 

 

 

 

Back

Condensate

 

 

3 / 4” FPT

 

 

Discharge

 

 

 

 

L

K CAP

J2

1

A

Front-View

CSP

3.25

[82.6mm]

 

F

Left

E

3

Discharge

 

 

D

 

 

 

Condensate

Back

 

3 / 4” FPT

Discharge

Q

P

Side

 

 

 

 

 

BSP

Blower

CoilAir

C

Front

 

 

 

 

O

 

Y

 

Outlet

 

 

R

 

 

 

 

 

A

 

 

 

Left Return Back Discharge

 

 

Unit Hanger Detail

 

 

X

 

Y

 

Z

MODEL

IN

CM

IN

CM

IN

CM

 

 

 

 

 

 

 

006-024

43.1

109.5

24.4

61.9

20.4

51.8

030-036

53.1

134.9

24.4

61.9

20.4

51.8

042-048

62.1

157.7

24.4

61.9

20.4

51.8

060

71.1

180.6

27.4

69.5

23.4

59.4

X

Z

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P

 

 

 

R

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Side

 

 

 

Blower

 

 

 

 

 

 

BSP

 

C

 

 

 

AirCoil

 

 

 

Outlet

 

O

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Q

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A

Right Return Back Discharge

 

P

M

ASP

Blower

BSP

Outlet

O

Front

 

N

 

 

N

 

P

 

BSP

CSP

Blower

O

Outlet

 

Front

Left Return Right Discharge

M

Right Return Left Discharge

 

 

VU

C T

 

 

 

 

 

1

 

 

 

S

 

 

 

 

Air Coil

[27.9mm]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CSP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Left Return

B

 

 

 

 

 

 

 

 

 

 

 

 

 

Left View -

 

 

 

Air Coil Opening

 

 

Air Coil

 

V

 

 

S

U

 

C

ASP

 

T

Front

Front

 

 

 

 

 

B

 

 

 

 

Right Return Right View -

 

 

 

 

Air Coil Opening

 

 

 

 

* Note: Shaded areas are recommended service areas, not required.

Fig. 1 — 50RHE Dimensional Data

4

Image 4
Contents Contents Safety ConsiderationsInstallation GeneralPhysical Data Aquazone 50RHE006-060 Units Unit 50RHELeft Return Right ReturnTypical Installation 50RHE Units Conversion Left Return, Side Discharge to Back Discharge Dimensions mm 50RHE Units030,036 042,048Typical Ground-Water Piping Installation Water Quality Guidelines Electrical WiringCondition Acceptable Level PSC CAPRVS FP1Comp Loss of Charge Pressure Switch Motorized Valve BMCBlower Motor Capacitor Performance Monitor Blower Relay Sensor, Air Coil Freeze ProtectionTypical Aquazone Deluxe D Control Wiring 3-Phase Unit 50RHE VOLTS-PHASE Voltage Compressor FAN Total MIN MAX Electrical DataUnit Circuit RLA LRA FUSE/HACR FLA50RHE Blower Performance 50RHEAirflow Unit SpeedLow Voltage Wiring See Fig PRE-START-UPControl Jumper Settings See Field Selectable InputsSTART-UP Control Accessory Relay ConfigurationsOperating Limits Unit Start-Up Cooling Mode Unit Start-Up Heating ModeWater Temperature Change Through Heat Exchanger Cooling HeatingTypical Unit Operating Pressures and Temperatures 50RHE Coaxial Water Pressure DropApproximate Fluid Volume L Per 30 m of Pipe Antifreeze Percentages by VolumeOperation Units with Aquazone Complete C ControlControl LED Code Fault Descriptions Control Current LED Status Alarm Relay OperationsSystem Test Service Alarm RelayDescription Status LED Test LED ESDGravity Flow Method Refrigerant Charging TroubleshootingAir Coil Fan Motor Removal Troubleshooting Fault Heating Cooling Possible Cause SolutionUnit Does Not Operate Page Page Copyright 2004 Carrier Corporation 50RHE R-407C Unit START-UP Checklist II. START-UPHeating Cycle Analysis Cooling Cycle Analysis

50RHE006-060 specifications

The Carrier 50RHE006-060 is a robust commercial rooftop unit designed for efficient heating and cooling in various applications. This model is part of Carrier’s renowned line of HVAC systems, known for their reliability and performance. With a nominal cooling capacity of 5 tons and heating capacity of 6 tons, this unit is suitable for medium-sized commercial spaces such as retail stores, offices, and schools.

One of the standout features of the Carrier 50RHE006-060 is its advanced scroll compressor technology. This type of compressor is recognized for its efficiency and durability, offering quiet operation while minimizing energy consumption. The inclusion of a variable-speed blower motor enhances comfort by providing consistent airflow while also reducing energy costs by adjusting the speed according to the demand.

Another key characteristic is its integrated microprocessor control system, which allows for precise temperature management. This feature not only provides optimal comfort but also ensures energy savings. The system’s controls can be easily integrated with existing building management systems, allowing for seamless operation and monitoring.

The Carrier 50RHE006-060 boasts enhanced insulation properties, which help reduce noise during operation and improve energy efficiency. Its robust design can withstand various weather conditions, making it a reliable choice for rooftop installation. Moreover, it is designed with accessibility in mind, featuring service doors that allow for easy maintenance, reducing downtime and operational costs.

In terms of efficiency, the unit is designed to meet or exceed EPA energy efficiency standards. It utilizes environmentally friendly refrigerants, adhering to regulations aimed at reducing greenhouse gas emissions. Additionally, the design includes a high-efficiency heat exchanger, which maximizes heat transfer and improves overall performance.

The Carrier 50RHE006-060 is also equipped with a dual-stage heat function, allowing it to provide optimal heating for varying weather conditions, ensuring comfort during the colder months. Furthermore, the unit’s design incorporates features such as hot gas bypass for improved dehumidification, making it adaptable to different climates and enhancing indoor air quality.

In summary, the Carrier 50RHE006-060 stands out with its efficient compressor technology, smart control systems, robust construction, and environmentally conscious design. These features make it a top choice for commercial spaces seeking an effective, reliable, and energy-efficient heating and cooling solution.