| Model |
| 2. Bend out the clips securing the rodent cover on the back of |
EVAPORATOR (Continued) | the unit, and pull the cover down. |
3.Disconnect the wires to the evaporator.
4.Pull up on the bottom of the evaporator to disengage the evaporator from the bracket. The evaporator is snapped into place. No hardware is securing it.
5.Replace evaporator in reverse order.
1. Open door and pull out on a corner of the seal until seal | |
| clears the retainer. |
2.Continue around the door, pulling the seal from the door.
3.Install new seal, starting with the four corners first.
603 |