Carrier 33PILOT-01 owner manual Zone Controller Default Screen

Page 2

NAVIGATE/

MODIFY/

EXIT

SELECT

Fig. 2 — Zone Controller Default Screen

Fig. 3 — Bypass Controller Default Screen

Fig. 4 — OAT Display Screen

User Interface — The System Pilot contains six buttons and two rotary knobs with buttons, which allow the user to navigate through the menus, select the desired options, and modify data. See Fig. 5.

SCROLL UP/SCROLL DOWN — If displaying a table or a list of items, these buttons move the cursor to the next line or previous line in the table or list.

If the System Pilot is displaying a controller Default screen and the SCROLL UP and SCROLL DOWN buttons are pressed together for 3 seconds, the System Pilot changes to Program mode.

Pressing the SCROLL UP button along with the INC/DEC button increases or decreases the contrast on the System Pilot LCD display screen.

PAGE UP/PAGE DOWN — In screens that have more than 7 data lines (Ex: a Table List screen with more than 7 tables, or a table with more than 7 decisions), these buttons replace the

606

SCROLL

+

PAGE

-

Fig. 5 — System Pilot User Interface

items currently on the screen with the previous or next 7 items from the table or list.

If there is additional data at the end or beginning of a table or list that is not on the screen, the cursor will not advance (move down) past the next-to-last line or up past the second line on the screen.

Linkage Coordinator Zone Controller Bus Scan — Pressing PAGE UP/PAGE DOWN together for 3 seconds from the Default screen of a Linkage Coordinator Zone Controller Default screen will display the Bus Scan screen. Bus Scan allows the user to scan through the linkage coordinator’s zones and display what is found at each address. Refer to Bus Scan section on page 7 for additional information on Linkage Coordinator Zone Controller Bus Scan.

INC/DEC — The INC and DEC buttons modify the value of the highlighted field within its defined limits.

From the Zone Controller Default screen, the INC/DEC buttons allow the user to modify the set points. Pressing the INC/DEC buttons continuously updates the highlighted field and the rate of change accelerates over time.

NAVIGATE — This rotary knob functions like the SCROLL UP/DOWN buttons, with the same sort of wrap-around. How- ever, it also incorporates a left-right movement. The cursor moves one selectable field with each increment of the rotary knob. Turning the knob clockwise moves the cursor to the right and down. With each increment, the cursor advances to the next field to the right on the current line. If the cursor is on the last field in the line, the cursor advances to the first (left-most) field in the next line. Turning the knob counterclockwise moves the cursor to the left and up in the same manner.

The NAVIGATE rotary knob also functions as the EXIT button when pressed.

EXIT — The EXIT button returns the display to the next high- er screen in the hierarchy. If the EXIT button is pressed and the data on the screen cannot be or has not been modified, the System Pilot moves to the next higher screen immediately (no additional prompts).

2

Image 2
Contents System Pilot Zone Controller Default Screen 606 Ctrl-→IDFig Program Screens Attach Screen System Pilot on Carrier Communicating NetworkTime Schedule Screen System Pilot Alternate Maintenance Tables Holiday Configuration Holdyxxs 3V Bus Scan ScreenCopyright 2004 Carrier Corporation

33PILOT-01 specifications

The Carrier 33PILOT-01 is a sophisticated air conditioning solution that exemplifies innovation in climate control technology. This model is designed to offer exceptional efficiency and performance, making it a popular choice for both residential and commercial applications.

One of the standout features of the 33PILOT-01 is its advanced inverter technology. This system adjusts the compressor speed based on the cooling demand, which not only maintains a consistent temperature but also significantly reduces energy consumption. By operating at variable speeds, the unit can achieve up to 30% energy savings compared to traditional fixed-speed systems. This efficiency translates into lower utility bills and a reduced carbon footprint, appealing to environmentally conscious consumers.

In addition to its energy efficiency, the Carrier 33PILOT-01 is equipped with a state-of-the-art air purification system. The multi-layer filtration process effectively removes dust, allergens, and pollutants from the air, providing a healthier indoor environment. The inclusion of an anti-bacterial filter ensures that the air stays clean, which is especially beneficial for individuals with allergies or respiratory issues.

Another notable technology in the 33PILOT-01 is the integration of smart connectivity features. Users can control the unit remotely via a smartphone app, allowing for convenient scheduling and temperature adjustments from anywhere. This smart technology is also compatible with voice assistants, adding an extra layer of convenience for tech-savvy homeowners.

The design of the Carrier 33PILOT-01 is both modern and functional. Its compact size makes it suitable for a variety of installation environments while maintaining an aesthetic appeal that blends seamlessly with contemporary interiors. The user-friendly interface features an intuitive display, making it easy for users to navigate settings and select specific modes.

Durability is a characteristic that Carrier products are known for, and the 33PILOT-01 is no exception. Constructed with high-quality materials and components, this unit is designed to withstand the rigors of daily use while delivering reliable performance year after year.

In summary, the Carrier 33PILOT-01 stands out in the air conditioning market due to its energy efficiency, advanced air purification, smart technology features, and durable design. It is an ideal choice for those seeking a modern cooling solution that meets both performance expectations and environmental considerations.