ELECTRICAL
EXTENSION CORDS
Use only
Length of Extension Cord | Wire Size (A.W.G.) |
Up to 25 feet | 14 |
12 |
When working with the tool outdoors, use an extension cord that is designed for outside use. This is indicated by the letters WA on the cord's jacket.
Before using an extension cord, inspect it for loose or exposed wires and cut or worn insulation. Repair or replace a damaged or worn cord immediately.
CAUTION:
Keep the cord away from the cutting area and position the cord so that it will not be caught on lumber, tools, or other objects during cutting.
ELECTRICAL CONNECTION
Your Ryobi Table Saw is powered by a precision built electric motor. It should be connected to a power supply that is 120 volts, 60Hz, AC only (normal household current). Do not operate this tool on direct current (DC). A substantial voltage drop will cause a loss of power and the motor will overheat. If the saw does not operate when plugged into an outlet, double check the power supply.
GROUNDING INSTRUCTIONS
In the event of a malfunction or breakdown, grounding provides a path of least resistance for electric current to reduce the risk of electric shock. This tool is equipped with an electric cord having an
Do not modify the plug provided. If it will not fit the outlet, have the proper outlet installed by a qualified electrician. Improper connection of the
Check with a qualified electrician or service personnel if the grounding instructions are not completely understood, or if in doubt as to whether the tool is properly grounded.
Repair or replace a damaged or worn cord immediately.
This tool is intended for use on a circuit that has an outlet like the one shown in Figure 1. It also has a grounding pin like the one shown.
COVER OF GROUNDED
OUTLET BOX
GROUNDING
PIN
Fig. 1
Page 7