Philips P-2220-E manual Ceramalux High Pressure Sodium Lamps, Property DAMAGE, Burns and Fire

Page 2

Ceramalux® High Pressure Sodium Lamps

Low total cost of ownership Long life—up to 24,000 hours High efficacy up to 140 LPW

ALTO® Lamp Technology passes EPA’s TCLP test for non-hazardous waste

Electrical,Technical and Ordering Data (Subject to change without notice)

 

 

 

 

 

ANSI

Std.

 

 

 

Rated

Approx.

Approx.

 

 

Product

Ordering

Nom.

 

 

Code/

Pkg.

 

LCL

MOL

Avg. Life

Initial

Mean

 

CCT

Number

Code

Watts

Bulb

Base

Ballast Ref.

Qty.

Description

(In.)

(In.)

Hrs.1

Lumens2

Lumens3

CRI

(K)

30632-4

C35S76/M

35

BD-17

Med.

S76

12

G (4, 6, 9, 12)

3716

5716

24,000+

2250

2025

21

2100

30633-2

C35S76/D/M

35

BD-17

Med.

S76

12

G (4, 6, 9, 12)

5716

24,000+

2150

1935

21

2100

30336-2

C50S68/M

50

BD-17

Med.

S68

12

G (4, 6, 9, 12)

3716

5716

24,000+

4000

3600

21

2100

30337-0

C50S68/D/M

50

BD-17

Med.

S68

12

G (4, 6, 9, 12)

5716

24,000+

3800

3420

21

2100

36867-0

C50S68/ALTO

50

ED-2312

Mog.

S68

12

G, S (4, 6, 9, 12)

5

734

24,000+

4000

3600

21

2100

33154-6

C50S68/D/ALTO

50

ED-2312

Mog.

S68

12

G, S (4, 6, 9, 12)

734

24,000+

3800

3420

21

2100

33192-6

C70S62/M

70

BD-17

Med.

S62

12

G (4, 6, 9, 12)

3716

5716

24,000+

6300

5850

21

2100

33214-8

C70S62/D/M

70

BD-17

Med.

S62

12

G (4, 6, 9, 12)

5716

24,000+

5860

5270

21

2100

36869-6

C70S62/ALTO

70

ED-2312

Mog.

S62

12

G, S (4, 6, 9, 12)

5

734

24,000+

6500

5670

21

2100

30620-9

C70S62/RFL

70

PAR-38

Med.

S62

12

G,VW, 50 (4, 6, 12, 13)

51316

16,000

5000

3960

21

2100

34446-5

C100S54/M

100

BD-17

Med.

S54S

12

G (4, 6, 9, 12)

312

5716

24,000+

9500

8550

21

2100

34448-1

C100S54/D/M

100

BD-17

Med.

S54S

12

G (4, 6, 9, 12)

5716

24,000+

8800

7920

21

2100

36872-0

C100S54/ALTO

100

ED-2312

Mog.

S54

12

G, S (4, 6, 9, 12)

5

734

24,000+

9400

8460

21

2100

33227-0

C100S54/D/ALTO

100

ED-2312

Mog.

S54

12

G, S (4, 6, 9, 12)

734

24,000+

8610

7750

21

2100

30347-9

C150S55/M

150

BD-17

Med.

S55

12

G (4, 6, 9, 12)

312

5716

24,000+

16,000

14,400

21

2100

30348-7

C150S55/D/M

150

BD-17

Med.

S55

12

G (4, 6, 9, 12)

5716

24,000+

15,000

13,500

21

2100

36874-6

C150S55/ALTO

150

ED-2312

Mog.

S55

12

G, S (4, 6, 7, 9, 12)

5

734

24,000+

15,800

14,220

21

2100

36876-1

C150S56/ALTO

150

ED-28

Mog.

S56

12

G, S (4, 6, 7, 9, 12)

5

81516

24,000+

15,000

13,950

21

2100

36877-9

C200S66/ALTO

200

ED-18

Mog.

S66MN-200

12

G, S (4, 6, 9, 12)

534

934

24,000+

21,400

19,260

21

2100

32291-7

C225S50/EW

225

ED-18

Mog.

S50

12

EW, G, S (4, 6, 9, 12, $)

534

934

24,000+

27,300

24,620

21

2100

36879-5

C250S50/ALTO

250

ED-18

Mog.

S50

12

G, S (4, 6, 9, 12)

534

934

24,000+

27,000

24,300

21

2100

13469-2

C310S67

310

ED-18

Mog.

S67

12

G (4, 6, 9)

534

934

24,000+

38,000

34,200

21

2100

32292-5

C360S51/EW

360

ED-18

Mog.

S51

12

EW, G, S (4, 6, 9, 12, $)

534

934

24,000+

46,000

41,450

21

2100

36881-1

C400S51/ALTO

400

ED-18

Mog.

S51

12

G, S (4, 6, 9, 12)

534

934

24,000+

50,000

45,000

21

2100

31710-7

SON AGRO/430W

430

ED-18

Mog.

S145/S51

12

AGRO (4, 6, 10, 11, 12)

534

934

16,000

54,000

48,600

21

2100

23982-2

C600S106

600

T-14

Mog.

S106

12

G (4, 6, 9, 12, 14)

678

1118

24,000+

90,000

81,000

21

2100

32386-5

C1000S52/ED37

1000

ED-37

Mog.

S52

6

G, S (4 6, 9, 12, 14)

7

1112

24,000+

125,000

112,000

21

2100

36883-7

C1000S52/ALTO

1000

E-25

Mog.

S52XB-1000

6

G, S (4, 5, 6, 8, 9, 12)

834

15116

24,000+

131,000

117,900

21

2100

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ceramalux® Comfort High Pressure Sodium Lamps

Improved color rendition of 65 CRI High efficacy

Warm white color appearance

Operates on standard HPS ballasts

Electrical,Technical and Ordering Data (Subject to change without notice)

 

 

 

 

 

ANSI

Std.

 

 

 

Rated

Approx.

Approx.

 

 

Product

Ordering

Nom.

 

 

Code/

Pkg.

 

LCL

MOL

Avg. Life

Initial

Mean

 

CCT

Number

Code

Watts

Bulb

Base

Ballast Ref.

Qty.

Description

(In.)

(In.)

Hrs.1

Lumens2

Lumens3

CRI

(K)

30617-5

C70S62/C/M

70

BD-17

Med.

S62

12

G (4, 6, 9, 12)

3 716

5 716

15,000

4400

3960

60

2200

30635-7

C100S54/C/M

100

BD-17

Med.

S54

12

G (4, 6, 9, 12)

3 716

5 716

15,000

7800

7020

60

2200

30637-3

C100S54/C

100

ED-231⁄2

Mog.

S54

12

G (4, 6, 9, 12)

5

7 34

15,000

7900

7110

60

2200

30647-2

C150S55/C/M

150

BD-17

Med.

S55

12

G (4, 6, 9, 12)

3 716

5 716

15,000

12,000

10,800

60

2200

30643-1

C150S55/C

150

ED-231⁄2

Mog.

S55

12

G (4, 6, 9, 12)

5

7 34

15,000

12,000

10,800

60

2200

30245-5

C250S50/C

250

ED-18

Mog.

S50

12

G (4, 6, 9, 12)

5 34

9 34

15,000

23,000

20,700

65

2200

30652-2

C400S51/C

400

ED-18

Mog.

S51

12

G (4, 6, 9, 12)

5 34

9 34

15,000

37,500

33,750

65

2200

WARNINGS, CAUTIONS AND OPERATING INSTRUCTIONS for Ceramalux® High Pressure Sodium Lamps

Warnings, Cautions and Operating Instructions

WARNING: These lamps must be operated in fixtures designed for use with High Pressure Sodium lamps.The fixture wattage rating must match the wattage indicated on the outer glass bulb. Do not scratch the outer bulb or subject it to pressure as this could cause the outer bulb to crack or shatter. A partial vacuum in the outer bulb may cause glass to fly if the glass is struck. Operating the lamp improperly may result in PERSONAL INJURY,

PROPERTY DAMAGE, BURNS AND FIRE.

1.If the outer glass bulb is broken, shut off power immediately and remove the lamp after it has cooled.

2.Use only auxiliary equipment meeting Philips and/or ANSI standards. Use within voltage limits recommended by ballast manufacturer.

A.Operate lamp only within specified limits of operation.

B.For total supply load refer to ballast manufacturers electrical data.

3.Protect lamp base, socket and wiring against moisture, corrosive atmospheres and excessive heat.

4.Replace the lamp if the outer glass bulb has been scratched, cracked or damaged in any way.

5.If a lamp bulb support is used, be sure to insulate the support electrically so as to avoid possible decomposition of the bulb glass.

6.Do not use this lamp in a fixture which redirects a substantial portion of the energy toward the arc tube and its immediate vicinity, as this may lead to very early lamp failure.

7.Take care in handling and disposing of lamps. If arc tube is broken, avoid skin contact with any of them contents or fragments.

8.The arc tube of this lamp contains sodium and mercury. Dispose of in accordance with federal, state and

local requirements.

Image 2
Contents Ceramalux High Pressure Sodium Lamps Property DAMAGE, Burns and Fire Ceramalux High Pressure Sodium LampsCeramalux Comfort High Pressure Sodium Lamps Instant Restrike High Pressure Sodium Lamps Ceramalux RetroLux High Pressure Sodium LampsLamp Operating Instructions MasterColor Ceramic Metal Halide HPS-Retro WhitePersonal INJURY, Property DAMAGE, Burns and Fire