P-2220-E

 

MasterColor® Ceramic Metal Halide HPS-Retro White

MasterColor technology optimized to operate in existing HPS fixtures, which means a simple, twist-of-the-wrist conversion

Improved work environment (crisp white light vs. yellow light) Better for the environment:TCLP-compliant

Replace yellow light with white light with just a simple twist! For operation on HPS ballasts; 85% lumen maintenance

No shut off required in 24-hour-a-day/7-day-a-week operations (relamp fixtures at or before the end of rated life)

Electrical,Technical and Ordering Data (Subject to change without notice)

 

 

 

 

 

 

ANSI

Std.

 

 

Rated

Approx.

Approx.

 

 

Product

Ordering

Nom.

 

 

 

Code/

Pkg.

LCL

MOL

Avg. Life

Initial

Mean

 

CCT

Number

Code

Watts

Bulb

Base

Ballast Ref.

Qty.

Description

(In.)

(In.)

Hrs.1

Lumens2

Lumens3

CRI

(K)

13093-0

CDM250S50/V/O/4K/ALTO

250

ED-18

Mog.

M168/O

12

G, Clear,Vertical ±15º (4, 5, 6)

5 34

9 34

20,000

22,500

19,125

85

4000

13094-8

CDM400S51/V/O/4K/ALTO

400

ED-18

Mog.

M169/O

12

G, Clear,Vertical ±15º (4, 5, 6)

5 34

9 34

20,000

34,000

28,900

85

4000

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WARNINGS, CAUTIONS AND OPERATING INSTRUCTIONS for Protected MasterColor® Ceramic Metal Halide HPS-Retro WhiteLamps ED-18 (Vertical Burn ± 15º, Open or Enclosed Fixtures)

Warnings, Cautions and Operating Instructions

R“WARNING: These lamps can cause serious skin burn and eye inflammation from short wave ultraviolet

radiation if outer envelope of the lamp is broken or punctured. Do not use where people will remain for more than a few minutes unless adequate shielding or other safety precautions are used. Certain lamps that will automatically extinguish when the outer envelope is broken or punctured are commercially available.”This lamp complies with FDA radiation performance standard 21 CFR subchapter J. (USA:21CFR 1040.30 Canada:SOR/DORS/80-381)

If the outer bulb is broken or punctured, turn off at once and replace the lamp to avoid possible injury from hazardous short wave ultraviolet radiation. Do not scratch the outer bulb or subject it to pressure as this could cause the outer bulb to crack or shatter.A partial vacuum in the outer bulb may cause glass to fly if the envelope is struck.

WARNING: The arc-tube of metal halide lamps are designed to operate under high pressure and at temperatures up to 1000º C and can unexpectedly rupture due to internal or external factors such as a ballast failure or misapplication. If the arc-tube ruptures for any reason, the outer bulb may break and pieces of extremely hot glass might be discharged into the surrounding environment. If such a rupture were to happen, THERE IS A RISK OF

PERSONAL INJURY, PROPERTY DAMAGE, BURNS AND FIRE.

These lamps are designed to retain all the glass particles should an arc tube rupture occur.The following operating instructions are recommended to minimize these occurrences.

RELAMP FIXTURES AT OR BEFORE THE END OF RATED LIFE.Allowing lamps to operate until they fail is not advised and may increase the possibility of inner arc tube rupture.

This lamp contains an arc tube with a filling gas containing Kr-85 and is distributed by Philips Lighting Company, a division of Philips Electronics North America Corporation, Somerset, New Jersey, 08875.

CAUTION: TO REDUCE THE RISK OF PERSONAL INJURY, PROPERTY DAMAGE, BURNS AND FIRE RESULTING FROM AN ARC-TUBE RUPTURE THE FOLLOWING LAMP OPERATING INSTRUCTIONS MUST BE FOLLOWED:

LAMP OPERATING INSTRUCTIONS:

1.RELAMP FIXTURES AT OR BEFORE THE END OF RATED LIFE. Allowing lamps to operate until they fail is not advised and may increase the possibility of inner arc tube rupture.

2.Before lamp installation/replacement, shut power off and allow lamp and fixture to cool to avoid electrical shock and potential burn hazards.

3.Use only auxiliary equipment meeting Philips and/or ANSI standards. Use within voltage limits recommended by ballast manufacturer.

A.Operate lamp only within specified limits of operation.

B.For total supply load refer to ballast manufacturers electrical data.

4.Periodically inspect the outer envelope. Replace any lamps that show scratches, cracks or damage.

5.If a lamp bulb support is used, be sure to insulate the support electrically to avoid possible decomposition of the bulb glass.

6.Protect lamp base, socket and wiring against moisture, corrosive atmospheres and excessive heat.

7.Time should be allowed for lamps to stabilize in color when turned on for the first time.This may require several hours of operation, with more than one start. Lamp color is also subject to change under conditions of excess vibration or shock and color appearance may vary between individual lamps.

8.Lamps may require 10 to 20 minutes to re-light if there is a power interruption.

9.Take care in handling and disposing of lamps. If an arc tube is broken, avoid skin contact with any of the contents or fragments.

FOOTNOTES for MasterColor® Ceramic Metal Halide HPS-Retro White® Lamps

1) Rated average life is the life obtained, on the average,

2) Approximate lumen values listed are for vertical

from large representative groups of lamps in laboratory

 

operation of the lamp.

tests under controlled conditions at 10 or more operat-

3) Approximate lumen output at 40% of lamp rated average life.

ing hours per start. It is based on survival of at least 50%

 

 

of the lamps and allows for individual lamps or groups of

4)

Performance may not be satisfactory unless operated

lamps to vary considerably from the average.

 

within specified operating positions.

 

5)

Heat resisting glass bulb.

6)MasterColor® Metal Halide Lamps are not recommended for use on dimmers and are not warranted if used on dimmer systems.

This product utilizes ALTO® Lamp Technology. ALTO products pass the US EPA's Toxicity Characteristic Leaching Procedure (TCLP) for non-hazardous waste status.

Image 4
Contents Ceramalux High Pressure Sodium Lamps Ceramalux Comfort High Pressure Sodium Lamps Ceramalux High Pressure Sodium LampsProperty DAMAGE, Burns and Fire Instant Restrike High Pressure Sodium Lamps Ceramalux RetroLux High Pressure Sodium LampsPersonal INJURY, Property DAMAGE, Burns and Fire MasterColor Ceramic Metal Halide HPS-Retro WhiteLamp Operating Instructions