Philips P-2220-E manual Instant Restrike High Pressure Sodium Lamps

Page 3

Instant Restrike High Pressure Sodium Lamps

Extra arc tube offers light instantly after momentary power interruption and will provide 80% light output within 1–2 minutes

For applications where instant restrike is not required, rated average life is 40,000 hours

Operates on standard HPS ballasts and auxiliary equipment

Electrical,Technical and Ordering Data (Subject to change without notice)

 

 

 

 

 

ANSI

Std.

 

 

 

Rated

Approx.

Approx.

 

 

Product

Ordering

Nom.

 

 

Code/

Pkg.

 

LCL

MOL

Avg. Life

Initial

Mean

 

CCT

Number

Code

Watts

Bulb

Base

Ballast Ref.

Qty.

Description

(In.)

(In.)

Hrs.1

Lumens2

Lumens3

CRI

(K)

35467-0

C50S68/2

50

ED-23 12

Mog.

S68

12

G, S (4, 6, 9, 12, 14)

5

7 34

24,000+

3800

3450

21

2100

26541-3

C70S62/2

70

ED-23 12

Mog.

S62

12

G, S (4, 6, 9, 12, 14)

5

7 34

24,000+

5600

5050

21

2100

26560-3

C100S54/2

100

ED-23 12

Mog.

S54

12

G, S (4, 6, 9, 12, 14)

5

7 34

24,000+

9100

8190

21

2100

26561-1

C150S55/2

150

ED-23 12

Mog.

S55

12

G, S (4, 6, 9, 12, 14)

5

7 34

24,000+

15,600

14,000

21

2100

37717-6

C250S50/2

250

ED-18

Mog.

S50

12

G, S (4, 6, 9, 12, 14)

5 34

9 34

24,000+

27,500

24,750

21

2100

37688-9

C400S51/2

400

ED-18

Mog.

S51

12

G, S (4, 6, 9, 12, 14)

5 34

9 34

24,000+

49,000

44,000

21

2100

20412-3

C1000S52/2

1000

E-25

Mog.

S52

6

G, S (4, 6, 9, 12, 14)

8 34

15 116

24,000+

140,000

126,000

21

2100

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

See previous page for Warnings, Cautions and Operating Instructions

Ceramalux® RetroLux High Pressure Sodium Lamps

For operation on all mercury vapor and metal halide ballasts of similar wattage 150W retrofits 175 watt mercury vapor or metal halide

220W retrofits 250 watt mercury vapor or metal halide 360W retrofits 400 watt mercury vapor or metal halide

Electrical,Technical and Ordering Data (Subject to change without notice)

 

 

 

 

 

ANSI

Std.

 

 

 

Rated

Approx.

Approx.

 

 

Product

Ordering

Nom.

 

 

Code/

Pkg.

 

LCL

MOL

Avg. Life

Initial

Mean

 

CCT

Number

Code

Watts

Bulb

Base

Ballast Ref.

Qty.

Description

(In.)

(In.)

Hrs.1

Lumens2

Lumens3

CRI

(K)

39194-6

C150S63/Retrolux

150

BT-28

Mog.

S63

12

G, S (12, $)

5 964

8 516

24,000

15,000

13,500

25

2100

39195-3

C220S65/Retrolux

220

BT-28

Mog.

S65

12

G, S (12, $)

5 964

8 516

24,000

25,000

22,500

25

2100

39196-1

C360S64/Retrolux

360

BT-37

Mog.

S64

6

G, S (12, $)

7 18

11 12

24,000

45,000

40,500

25

2100

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WARNINGS, CAUTIONS AND OPERATING INSTRUCTIONS for Ceramalux® RetroLux High Pressure Sodium Lamps

Warnings, Cautions and Operating Instructions

CAUTION: Electric discharge lamp—Use only with proper circuits and auxiliary equipment designed to produce established electrical values for this lamp. Operating the lamp improperly may result in damage to equipment or personal injury, for which the lamp manufacturer does not assume any responsibility.

If a lamp bulb support is used, be sure to insulate the support electrically to avoid possible decomposition of the bulb glass. Do not scratch the bulb or subject it to pressure, as it could fail violently. If the outer bulb is broken, turn off the lamp and replace it promptly.

The arc tube of this lamp contains sodium and mercury. Use appropriate care in disposal. Protect lamp base, socket and wiring against moisture, corrosive atmospheres and excessive heat.

Do not use this lamp in a fixture which redirects a substantial portion of the energy toward the arc tube and its immediate vicinity, as this may lead to very early lamp failure.

NOTICE: For total supply load, add auxiliary (ballast) watts to lamp watts.

FOOTNOTES for Ceramalux® High Pressure Sodium Lamps

1)Rated average life is the life obtained, on the average, from large representative groups of lamps in laboratory tests under controlled conditions at 10 or more operating hours per start. It is based on survival of at least 50% of the lamps and allows for individual lamps or groups of lamps to vary considerably from the average. For lamps with a rated average life of 24,000 hours, life is based on survival of 67% of the lamps.

2)Approximate lumen values listed are for vertical operation of the lamp.

3)Approximate lumen output at 40% of lamp rated average life.

4)Follow fixture manufacturer’ recommendations regarding proximity of ballast to bulb.

5)Electrically insulated support for bulb may be required, especially in horizontal and nearly horizontal operating positions.

6)Fixtures should be designed so that sockets and wiring withstand starting pulse up to 5000 volts for 1000 watts and WHITE SON® types and 4000 volts for other sizes.

7)C150S55 and C150S56 lamps are not electrically interchangeable. Different ballasts are required for the proper operation of each lamp type. ANSI type S55 ballast is for the 55-volt (normal) lamp and the ANSI type S56 ballast is for the 100 volt (nominal) lamp.

8)This lamp should be shielded from moisture to prevent breakage.

9)For use in fixtures which do not redirect a substantial portion of the energy toward the arc tube; otherwise very early failure is anticipated.

10)Operates at rated output on ANSI 400W S145 ballasts.

11)UV filtered design (FadeBlock).

12)Heat resisting glass bulb.

13)PAR-38 (one piece)

14)Nickel plated brass base.

This product utilizes ALTO® Lamp Technology. ALTO products pass the US EPA's Toxicity Characteristic Leaching Procedure (TCLP) for non-hazardous waste status.

Image 3
Contents Ceramalux High Pressure Sodium Lamps Ceramalux High Pressure Sodium Lamps Ceramalux Comfort High Pressure Sodium LampsProperty DAMAGE, Burns and Fire Ceramalux RetroLux High Pressure Sodium Lamps Instant Restrike High Pressure Sodium LampsMasterColor Ceramic Metal Halide HPS-Retro White Personal INJURY, Property DAMAGE, Burns and FireLamp Operating Instructions