Instant Restrike High Pressure Sodium Lamps
◗Extra arc tube offers light instantly after momentary power interruption and will provide 80% light output within
◗For applications where instant restrike is not required, rated average life is 40,000 hours
◗Operates on standard HPS ballasts and auxiliary equipment
Electrical,Technical and Ordering Data (Subject to change without notice)
|
|
|
|
| ANSI | Std. |
|
|
| Rated | Approx. | Approx. |
|
|
Product | Ordering | Nom. |
|
| Code/ | Pkg. |
| LCL | MOL | Avg. Life | Initial | Mean |
| CCT |
Number | Code | Watts | Bulb | Base | Ballast Ref. | Qty. | Description | (In.) | (In.) | Hrs.1 | Lumens2 | Lumens3 | CRI | (K) |
C50S68/2 | 50 | Mog. | S68 | 12 | G, S (4, 6, 9, 12, 14) | 5 | 7 3⁄4 | 24,000+ | 3800 | 3450 | 21 | 2100 | ||
C70S62/2 | 70 | Mog. | S62 | 12 | G, S (4, 6, 9, 12, 14) | 5 | 7 3⁄4 | 24,000+ | 5600 | 5050 | 21 | 2100 | ||
C100S54/2 | 100 | Mog. | S54 | 12 | G, S (4, 6, 9, 12, 14) | 5 | 7 3⁄4 | 24,000+ | 9100 | 8190 | 21 | 2100 | ||
C150S55/2 | 150 | Mog. | S55 | 12 | G, S (4, 6, 9, 12, 14) | 5 | 7 3⁄4 | 24,000+ | 15,600 | 14,000 | 21 | 2100 | ||
C250S50/2 | 250 | Mog. | S50 | 12 | G, S (4, 6, 9, 12, 14) | 5 3⁄4 | 9 3⁄4 | 24,000+ | 27,500 | 24,750 | 21 | 2100 | ||
C400S51/2 | 400 | Mog. | S51 | 12 | G, S (4, 6, 9, 12, 14) | 5 3⁄4 | 9 3⁄4 | 24,000+ | 49,000 | 44,000 | 21 | 2100 | ||
C1000S52/2 | 1000 | Mog. | S52 | 6 | G, S (4, 6, 9, 12, 14) | 8 3⁄4 | 15 1⁄16 | 24,000+ | 140,000 | 126,000 | 21 | 2100 | ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
See previous page for Warnings, Cautions and Operating Instructions
Ceramalux® RetroLux High Pressure Sodium Lamps
◗For operation on all mercury vapor and metal halide ballasts of similar wattage ◗150W retrofits 175 watt mercury vapor or metal halide
◗220W retrofits 250 watt mercury vapor or metal halide ◗360W retrofits 400 watt mercury vapor or metal halide
Electrical,Technical and Ordering Data (Subject to change without notice)
|
|
|
|
| ANSI | Std. |
|
|
| Rated | Approx. | Approx. |
|
|
Product | Ordering | Nom. |
|
| Code/ | Pkg. |
| LCL | MOL | Avg. Life | Initial | Mean |
| CCT |
Number | Code | Watts | Bulb | Base | Ballast Ref. | Qty. | Description | (In.) | (In.) | Hrs.1 | Lumens2 | Lumens3 | CRI | (K) |
C150S63/Retrolux | 150 | Mog. | S63 | 12 | G, S (12, $) | 5 9⁄64 | 8 5⁄16 | 24,000 | 15,000 | 13,500 | 25 | 2100 | ||
C220S65/Retrolux | 220 | Mog. | S65 | 12 | G, S (12, $) | 5 9⁄64 | 8 5⁄16 | 24,000 | 25,000 | 22,500 | 25 | 2100 | ||
C360S64/Retrolux | 360 | Mog. | S64 | 6 | G, S (12, $) | 7 1⁄8 | 11 1⁄2 | 24,000 | 45,000 | 40,500 | 25 | 2100 | ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
WARNINGS, CAUTIONS AND OPERATING INSTRUCTIONS for Ceramalux® RetroLux High Pressure Sodium Lamps
Warnings, Cautions and Operating Instructions
CAUTION: Electric discharge
If a lamp bulb support is used, be sure to insulate the support electrically to avoid possible decomposition of the bulb glass. Do not scratch the bulb or subject it to pressure, as it could fail violently. If the outer bulb is broken, turn off the lamp and replace it promptly.
The arc tube of this lamp contains sodium and mercury. Use appropriate care in disposal. Protect lamp base, socket and wiring against moisture, corrosive atmospheres and excessive heat.
Do not use this lamp in a fixture which redirects a substantial portion of the energy toward the arc tube and its immediate vicinity, as this may lead to very early lamp failure.
NOTICE: For total supply load, add auxiliary (ballast) watts to lamp watts.
FOOTNOTES for Ceramalux® High Pressure Sodium Lamps
1)Rated average life is the life obtained, on the average, from large representative groups of lamps in laboratory tests under controlled conditions at 10 or more operating hours per start. It is based on survival of at least 50% of the lamps and allows for individual lamps or groups of lamps to vary considerably from the average. For lamps with a rated average life of 24,000 hours, life is based on survival of 67% of the lamps.
2)Approximate lumen values listed are for vertical operation of the lamp.
3)Approximate lumen output at 40% of lamp rated average life.
4)Follow fixture manufacturer’ recommendations regarding proximity of ballast to bulb.
5)Electrically insulated support for bulb may be required, especially in horizontal and nearly horizontal operating positions.
6)Fixtures should be designed so that sockets and wiring withstand starting pulse up to 5000 volts for 1000 watts and WHITE SON® types and 4000 volts for other sizes.
7)C150S55 and C150S56 lamps are not electrically interchangeable. Different ballasts are required for the proper operation of each lamp type. ANSI type S55 ballast is for the
8)This lamp should be shielded from moisture to prevent breakage.
9)For use in fixtures which do not redirect a substantial portion of the energy toward the arc tube; otherwise very early failure is anticipated.
10)Operates at rated output on ANSI 400W S145 ballasts.
11)UV filtered design (FadeBlock™).
12)Heat resisting glass bulb.
13)
14)Nickel plated brass base.
This product utilizes ALTO® Lamp Technology. ALTO products pass the US EPA's Toxicity Characteristic Leaching Procedure (TCLP) for