Fluke 187 Using Memory & Communications Features, Types of Memory, Saved Readings Memory

Page 63

Chapter 4

Using Memory & Communications Features

Introduction

Chapter 4 shows you how to use memory and communication features available on the meters.

Note

Memory, Logging, and Save features apply to the 189 only.

Types of Memory

The meter has two types of memory data: saved readings and logged readings.

Saved Readings Memory

Saved readings include primary and secondary readings and functions, the time stamp, and display icons representing various features in effect.

Logged Readings Memory

The logging interval (Log Int) can be set using the meter or FlukeView Forms. You can view the average reading for each logging interval on the meter’s display. A scheduled logging interval may contain stable and unstable logged readings. Unstable logged readings represent unstable events as defined by the AutoHOLD function. See the Specifications.

To provide more detailed logging information, the meter also stores the high, low, and average value for each set of stable and unstable logged readings. You can only access these logged readings using FlukeView Forms.

Some of the logged readings can only be accessed using a PC running the FlukeView Forms software. FlukeView Forms displays the data in graphical or tabular form, prints, and stores the data.

4-1

Image 63
Contents Model 187 Lifetime Limited Warranty Table of Contents Making Measurements Model 187Iii Specifications MaintenanceList of Tables List of Figures Viii Safety Information Before You StartContacting Fluke WWarning Safety InformationBefore You Start International Electrical Symbols SymbolsGetting Acquainted IntroductionTurning the Meter On Automatic Power Off Battery ConsiderationsAutomatic Backlight Off Low Battery IndicationRotary Switch Rotary SwitchPushbuttons PushbuttonsBlue Key Function Rotary Switch Selections Position Rotary Switch FunctionView MEM Rotary Switch PositionsButton Pushbuttons Yellow Button Description Function Yellow Button Function Pushbuttons Button DescriptionSelecting the Range Understanding the DisplayPrimary Display Secondary Display Bar GraphDisplay Features Number Feature Display Features Description 8.8.8 Display Features NumberDisplay Features Description Number FeatureFMS8888 HM8888 8.8 Display Features Number 51000Input Terminals Using the Input TerminalsDisplay Hold and AutoHOLD Using Display HoldUsing MIN MAX Using AutoHOLDModel 187 Min Max Avg Using Fast MN MXUsing Hold with MIN MAX or Fast MN MX Using Relative Mode RELMeasuring Voltage Making MeasurementsAC Voltage Measurement Measuring AC VoltageDBm Display DB Measurements in AC Volts FunctionsBoth AC and DC Voltage Measurements Measuring DC VoltageAC and DC Display AC over DC DC over ACCapacitors before measuring resistance Measuring ResistanceOFF Automatically subtract this value Testing for ContinuityUsing Conductance for High Resistance Tests For in-circuit tests, turn circuit power off Conductance Measurement Measuring Capacitance Capacitance Measurement Testing DiodesDiode Test Measuring Temperature Shock, do not connect the thermocouples toElectrically live circuits Input Ranges Measuring CurrentMeasuring Current Input Alert FeatureFollowing are some tips for measuring current Measuring AC Current11. AC Current Measurement Measuring DC Current Current through one component Total current to circuit13. Functions Allowing Frequency Measurement Measuring Frequency14. Hz Display Measuring Duty CycleMeasures Negative Pulse Measures Positive Pulse16. Duty Cycle Display Measuring Pulse WidthStart and Stop on Negative Slope Start and Stop on Positive Slope18. Pulse Width Display Logged Readings Memory Using Memory & Communications FeaturesTypes of Memory Saved Readings MemoryStoring Saved Readings Starting LoggingStopping Logging To avoid electric shock, disconnect the test Viewing Memory DataMEM View DisplayClearing Memory Using Communications 187Selecting Setup Options Changing the Default SettingsOption Function Specific Setup SelectionsFactory Default PreconditionChoices Common Setup SelectionsAdjusting the Temperature Offset Changing the Default Settings Setting the Power Off Timeout Selecting Display Resolution 3 1/2 or 4 1/2 DigitsSetting the Line Main Frequency Setting the 24-Hour ClockSaving Setup Options Returning to Factory DefaultsMaintenance Introduction General MaintenanceTesting the Fuses Replace F2 if Replace F1 if Displayed Replacing the Batteries Battery and Fuse Replacement Replacing the Fuses User-Replaceable PartsCase of Difficulty MP8 MP9 Safety and Compliances SpecificationsPhysical Specifications Feature Summary Basic Specifications Detailed Accuracy Specifications KHz-100 kHz Accuracy Function45-1 kHz 20 kHzDC a 500.00 Ω Capacitance Diode Test MIN MAX AVG Burden Voltage A, mA, µA Frequency Counter SensitivityInput Characteristics