Fluke 187 user manual Feature Summary

Page 84

Specifications

Feature Summary 7

Feature Summary

Feature

Dual Digital Displays

Analog Bar Graph

Backlight with 2 brightness levels

Fast Autorange

AC+DC true rms, ac rms specified to 100 kHz

dBm, dBV

AutoHOLD

Continuity / Open test

 

Description

Primary:

50,000 counts

Secondary:

5,000 count

Bar graph:

51 segments, updates 40 times/second

Bright white backlight for clear readings in poorly lighted areas

Meter automatically selects best range - instantly

Choices for AC only, AC and DC dual display, or AC+DC readings

User selectable impedance references for dBm

Holds readings on display

Beeper sounds for resistance readings below threshold, or to indicate a momentary open circuit

Fast Bar Graph

Duty cycle / Pulse width

MIN MAX Mode

FAST MN MX with 24-hour time stamp

Closed-Case Calibration

Battery / Fuse Access Door

Hi-Impact Overmolded Case

51 segments for peaking and nulling

Measure signal on or off time in % or milliseconds

Record maximum, minimum, and average values.

24-hour clock for MAX or MIN, elapsed time for AVG. FAST MN MX captures peaks to 250 sec.

No internal adjustments needed

Battery or fuse replaceable without voiding calibration

Protective holster features

7-3

Image 84
Contents Model 187 Lifetime Limited Warranty Table of Contents Model 187 Making MeasurementsIii Maintenance SpecificationsList of Tables List of Figures Viii Safety Information Before You StartContacting Fluke Safety Information WWarningBefore You Start Symbols International Electrical SymbolsGetting Acquainted IntroductionTurning the Meter On Battery Considerations Automatic Power OffLow Battery Indication Automatic Backlight OffRotary Switch Rotary SwitchPushbuttons PushbuttonsRotary Switch Selections Position Rotary Switch Function Blue Key FunctionRotary Switch Positions View MEMButton Pushbuttons Yellow Button Description Function Pushbuttons Button Description Yellow Button FunctionSelecting the Range Understanding the DisplayPrimary Display Bar Graph Secondary DisplayDisplay Features Number Feature Display Features Description Display Features Number 8.8.8Number Feature Display Features DescriptionDisplay Features Number 51000 FMS8888 HM8888 8.8Using the Input Terminals Input TerminalsUsing Display Hold Display Hold and AutoHOLDUsing AutoHOLD Using MIN MAXModel 187 Using Fast MN MX Min Max AvgUsing Relative Mode REL Using Hold with MIN MAX or Fast MN MXMaking Measurements Measuring VoltageMeasuring AC Voltage AC Voltage MeasurementDB Measurements in AC Volts Functions DBm DisplayMeasuring DC Voltage Both AC and DC Voltage MeasurementsAC over DC DC over AC AC and DC DisplayMeasuring Resistance Capacitors before measuring resistanceOFF Testing for Continuity Automatically subtract this valueUsing Conductance for High Resistance Tests For in-circuit tests, turn circuit power off Conductance Measurement Measuring Capacitance Testing Diodes Capacitance MeasurementDiode Test Measuring Temperature Shock, do not connect the thermocouples toElectrically live circuits Measuring Current Input RangesInput Alert Feature Measuring CurrentMeasuring AC Current Following are some tips for measuring current11. AC Current Measurement Measuring DC Current Total current to circuit Current through one componentMeasuring Frequency 13. Functions Allowing Frequency MeasurementMeasuring Duty Cycle 14. Hz DisplayMeasures Positive Pulse Measures Negative PulseMeasuring Pulse Width 16. Duty Cycle DisplayStart and Stop on Positive Slope Start and Stop on Negative Slope18. Pulse Width Display Using Memory & Communications Features Types of MemorySaved Readings Memory Logged Readings MemoryStoring Saved Readings Starting LoggingStopping Logging Viewing Memory Data To avoid electric shock, disconnect the testView Display MEMUsing Communications 187 Clearing MemoryChanging the Default Settings Selecting Setup OptionsFunction Specific Setup Selections Factory DefaultPrecondition OptionCommon Setup Selections ChoicesAdjusting the Temperature Offset Changing the Default Settings Selecting Display Resolution 3 1/2 or 4 1/2 Digits Setting the Power Off TimeoutSetting the 24-Hour Clock Setting the Line Main FrequencyReturning to Factory Defaults Saving Setup OptionsMaintenance Introduction General MaintenanceTesting the Fuses Replace F2 if Replace F1 if Displayed Replacing the Batteries Battery and Fuse Replacement Replacing the Fuses User-Replaceable PartsCase of Difficulty MP8 MP9 Specifications Safety and CompliancesPhysical Specifications Feature Summary Basic Specifications Detailed Accuracy Specifications Accuracy Function 45-1 kHz20 kHz KHz-100 kHzDC a 500.00 Ω Capacitance Diode Test MIN MAX AVG Frequency Counter Sensitivity Burden Voltage A, mA, µAInput Characteristics