Hobart OM-186 165C manual Calibrating Optional IPM Meter, Nonconductive

Page 20

4-3. Calibrating Optional IPM Meter

1

A

6

5

B

0

15

2

3

4

Nonconductive

C

Meter is factory calibrated, but may need recalibration after motor brushes are fully seated. To recali- brate, proceed as follows:

1CV/CC Switch Set switch to CV.

2Meter Board PC4

3Resistor R53 Adjustment Screw (High Range)

4Resistor R54 Adjustment Screw (Low Range)

Calibrate Low range wire speed first.

5Wire Speed Range Switch

6Wire Speed Control

ASet range switch to Low, and control to about 50%. Turn wire feeder and weld- ing power source On.

BPress trigger and feed wire for 15 seconds. Measure wire length, and multiply x 4 to get actual ipm. For ex- ample: If 49 inches feeds in 15 sec, 49 x 4 = 196 actual ipm.

CPress trigger again: Meter reading should match ac- tual ipm value, 196 in ex- ample. If not, press trigger and carefully adjust R54 until meter reads 196.

After Low range is calibrated, set range switch to High. Leave control at same setting (about 380 ipm). Repeat procedure to calibrate High range wire speed: About 95 inches should feed in 15 sec, 95 x 4 = 380 ipm. If needed, adjust R53 so meter reading matches actual ipm.

Turn off power. Close and latch door.

Ref. ST-800 586-B / Ref. ST-176 180

OM-186 165 Page 16

Image 20
Contents Description OM-186 165CProcesses From Hobart to You Table of Contents Page Symbol Usage Marks a special safety messageArc Welding Hazards Electric Shock can killARC Rays can burn eyes and skin Welding can cause fire or explosionFlying Metal can injure eyes Buildup of GAS can injure or killPrincipal Safety Standards EMF Information About PacemakersSignification des symboles Consignes DE Securite Lire Avant UtilisationUN Choc É Lectrique peut tuer LES Fumé ES ET LES GAZ peuvent ê tre dangereuxLE Bruit peut affecter l’ouïe LE Soudage peut provoquer un incendie ou une explosionDES Particules Volantes peuvent blesser les yeux Risque D’INCENDIE OU LA Chute DE L’APPAREIL peut blesser’EMPLOI Excessif peut DES Organes Mobiles peuvent provoquer des blessuresConsignes relatives aux stimulateurs cardiaques Principales normes de sé curitéInformation sur les champs é lectromagné tiques Installation SpecificationsPower DiameterInstalling And Aligning Wire Guide And Drive Roll Installing Wire Guide And Drive RollsAligning Wire Guide And Drive Rolls Cleaning Drive RollsGun Recommendation Table Connecting Welding Gun And Voltage Sensing LeadTypical Connections Connecting Shielding Gas Optional Connecting Weld CableThreading Welding Wire Installing And Threading Welding WireInstalling Wire And Adjusting Hub Tension Operation ControlsMaintenance & Troubleshooting Routine MaintenanceMonths Overload ProtectionCalibrating Optional IPM Meter NonconductiveTroubleshooting Trouble RemedyElectrical Diagram Circuit Diagram For Wire FeederOM-186 165 Complete Complete Assembly 118 Optional Drive Roll & Wire Guide Kits 2 Drive Roll OM-186 165 OM-186 165 Service SupportContact your Distributor for Hobart Welding Products