Hobart Welding Products OM-948 manual Safety Information, Installation, Specifications

Page 7

SECTION 2 – SAFETY INFORMATION

Read all safety messages throughout this manual.

Obey all safety messages to avoid injury.

Learn the meaning of WARNING and CAUTION.

1 2

WARNING

ELECTRIC SHOCK can kill.

Do not touch live electrical parts.

Disconnect input power before installing or servicing.

5

3

4

2

CAUTION

MOVING PARTS can injure.

Keep away from moving parts.

Keep all panels and covers closed

when operating.

1Safety Alert Symbol

2Signal Word

WARNING means possible death or serious injury can happen.

CAUTION means possible minor injury or equipment damage can happen.

3

Statement Of Hazard And

 

Result

4

Safety Instructions To Avoid

 

Hazard

6

WARNING

READ SAFETY BLOCKS at start of

 

Section 3-1 before proceeding.

7

NOTE

Turn Off switch when using high frequency.

5

Hazard Symbol (If Available)

6

Safety Banner

Read safety blocks for each symbol shown.

7 NOTE

Special instructions for best operation – not related to safety.

SECTION 3 – INSTALLATION

3-1. Specifications

Air-Cooled Welding Gun For FCAW And GMAW Welding

Note: Using gasless flux cored wire reduces gun duty cycle.

H-9 Feeds .030 To .035 in (0.8 To 0.9 mm) Flux Cored Wire Or .024 To .030 in (0.6 To 0.8 mm) Hard Wire

Duty Cycle Rating:

100%: 40 A With Flux Cored Wire

100%: 100 A With CO2 Shielding Gas

60%: 100 A With Mixed Gases

Weight With 8 ft (2.4 m) Power Cable: 2.2 lb (1.0 kg)

803 495-A

3-2. Duty Cycle And Overheating

 

See Section 3-1. Specifications for amperage

Duty Cycle is percentage of 10

 

rating and duty cycle.

minutes that unit can weld at rated

 

 

load without overheating.

 

 

60%dutycycle

Y Exceeding duty

cycle

can

100%dutycycle

damage unit

and

void

 

 

 

warranty.

 

 

Continuous Welding

6 Minutes Welding

4 Minutes Resting

 

 

Overheating

 

A or V

 

0

 

 

15

 

 

OR

 

Minutes

Reduce Duty Cycle

 

 

sduty1 5/95

OM-948 Page 3

Image 7
Contents Gun From Hobart to You Table of Contents Page Fcaw And Gmaw Gun Hazards Symbol UsageMarks a special safety message Means Note not safety relatedAbout Pacemakers EMF InformationDuty Cycle And Overheating Safety InformationInstallation SpecificationsIf existing gun requires removal, see Section Installing Gun Into Welding Power SourceTurn off welding power source Thread wire according to SectionHold wire tightly to keep it from unraveling Threading Welding WireOperating The Gun OperationCleaning Gun Liner Maintenance & TroubleshootingReplacing Gun Contact Tip Replacing Gun Liner Replacing Gun Liner Replacing Liner O-Ring Replacing Liner O-Ring Replacing Switch And/Or Head Tube Removing Gun From Welding Power Source Months Routine MaintenanceEach Spool Of Wire TroubleshootingPkg Parts ListWork like a Pro Page Page Support ServiceOwner’s Record