Carrier 012, 50LJQ008 installation instructions Unit MAX Dimensions Weight

Page 3

MAXIMUM ALLOWABLE DIFFERENCE

A-B

 

B-C

 

A-C

 

mm

 

in.

mm

 

in.

mm

 

in.

13

 

.5

25

 

1.0

25

 

1.0

Fig. 2 Ð Unit Leveling Tolerance

Step 3 Ð Make Field Connection for Conden- sate Disposal Ð Units must have an external trap added. See Fig. 3. A 3¤4-in. FPT connection is located on the side of the unit. Use a trap at least 100 mm (4 in.) deep, and protect against freeze-up.

If drain line is run to a drain, pitch line away from unit at 25 mm (one in.) per 3 m (10 ft) of run. Do not use a pipe size smaller than the unit connection.

Step 4 Ð Rig and Place Unit Ð Inspect unit for trans- portation damage. File any claim with transportation agency. Keep unit upright and do not drop. Spreader bars are not required if top crating is left on unit. Rollers may be used to move unit across a roof. Level by using unit frame as a ref- erence. See Tables 1A and 1B and Fig. 4 for additional in- formation. Operating weight is shown in Tables 1A and 1B and Fig. 4.

Lifting holes are provided in base rails as shown in Fig. 4 and 5. Refer to rigging instructions on unit.

NOTES:

1. Dimensions in ( ) is in millimeters.

2.Hood rigging shackles through holes in base rail, as shown in detail ``A''. Holes in base rails are centered around the unit center of gravity. Use wooden top skid when rigging to prevent rigging straps from damaging unit.

3.Weights do not include economizer. See Tables 1A and 1B for econo- mizer weights.

All panels must be in place when rigging.

All panels must be in place when rigging.

POSITIONING Ð Maintain clearance around and above unit to provide proper air ¯ow and service access. See Fig. 5.

Position unit on roof curb so that the following clearances are maintained; 6 mm (1¤4 in.) clearance between roof curb and base rails on each side and front of unit: 29 mm (15¤32 in.) clearance between roof curb and rear of unit (see Fig. 1, section C-C).

Do not install unit in an indoor location. Do not locate unit air inlet near exhaust vents or other sources of contami- nated air.

Although unit is weatherproof, guard against water from higher level runoff and overhangs.

After unit is in position, remove polyethylene shipping wrap- per and rigging skid.

NOTE: Trap should be deep enough to offset maximum unit static difference. A 100 mm (4 in.) trap is recommended.

Fig. 3 Ð External Trap Condensate Drain

UNIT

MAX

 

 

DIMENSIONS

 

 

WEIGHT

``A''

``B''

``C''

50LJQ

 

lb

kg

in.

mm

in.

mm

in.

mm

008

840

381

87.38

2219

40.25

1022

41.31

1050

012

940

426

87.38

2219

40.25

1022

48.31

1253

 

 

 

 

 

 

 

 

 

Fig. 4 Ð Rigging Details

3

Image 3
Contents Installation, Start-Up and Service Instructions PKG. ACC Roof Curb ``A Unit Size AccessoryUnit Size ``F Power Connector50LJQ Unit MAX Dimensions WeightÐ Physical Data SI Base Unit 50QJ Ð Physical Data English``H ``J Weight ``BWeight ``D 50LJQ Unit STD. Unit Economizer CornerEquip GNDHTR Page Equip Equip Electrical Data American/European Wire Conversions Unit VoltageAmerican European DAT Unit Heater Required ConfigBAT OFC50LJQ Motor Pulley Turns Open Ð Fan Rpm at Motor Pulley Settings EnglishAirflow 2400 482 External Static Pressure in. wgRpm Bhp 2200 459START-UP OFC Ð Outdoor-Fan Contactor ContactorHeater Contactor OAT Ð Outdoor-Air ThermostatService Lubrication Cooling Charging Charts, 50LJQ008 Page Page Copyright 1992 Carrier Corporation

012, 50LJQ008 specifications

The Carrier 012,50LJQ008 is a state-of-the-art air conditioning unit, specifically designed to provide optimal temperature control and energy efficiency for residential and commercial applications. As part of Carrier's renowned portfolio, this model incorporates innovative technologies and user-friendly features that set it apart from competitors in the market.

One of the standout characteristics of the Carrier 012,50LJQ008 is its high energy efficiency rating. Equipped with advanced inverter technology, this unit adjusts its cooling output based on the ambient temperature and humidity levels, reducing energy consumption while maintaining consistent comfort. This not only lowers utility bills but also minimizes the environmental impact, making it a sustainable choice for modern living.

In terms of cooling capacity, the Carrier 012,50LJQ008 offers a formidable performance, capable of efficiently cooling spaces of varying sizes. Its robust compressor ensures rapid cooling while remaining remarkably quiet, which is particularly advantageous for residential settings. The unit’s capacity to handle high ambient temperatures allows it to perform reliably even in extreme weather conditions, ensuring comfort during the hottest days of summer.

Another key feature is the user-friendly interface. The Carrier 012,50LJQ008 comes with a digital control panel that allows users to easily set their desired temperature and adjust fan speeds according to their preferences. Additionally, it offers remote control functionality, providing convenience and ease of use for homeowners and occupants alike.

The design of the Carrier 012,50LJQ008 incorporates advanced air filtration technology, including a multi-layer filter system that captures allergens and airborne particles. This not only improves indoor air quality but also contributes to the longevity of the unit by preventing dust buildup. The filters are easily accessible for cleaning and replacement, ensuring the system runs efficiently.

Durability is another critical aspect of this model. Constructed with high-quality materials, the Carrier 012,50LJQ008 is designed to withstand varying environmental conditions. Its corrosion-resistant outdoor unit ensures a longer lifespan, while comprehensive warranties provide peace of mind to users.

In summary, the Carrier 012,50LJQ008 is an exemplary air conditioning unit that combines energy efficiency, advanced technology, and user-centric features. Whether for a family home or a commercial space, its superior performance, reliability, and ease of use make it an excellent choice for maintaining optimal comfort year-round.