Carrier 012, 50LJQ008 installation instructions Airflow

Page 15

Table 6 Ð Fan Performance (SI), 50LJQ008 (50 Hz) Ð Horizontal Discharge Units

AIRFLOW

 

 

 

 

 

 

 

 

EXTERNAL STATIC PRESSURE (Pa)

 

 

 

 

 

 

 

 

 

 

 

50

100

150

200

250

300

350

400

450

500

(L/s)

 

 

r/s

 

BkW

r/s

BkW

r/s

BkW

r/s

BkW

r/s

BkW

r/s

BkW

r/s

BkW

r/s

 

BkW

r/s

 

BkW

r/s

 

BkW

1100

7.9

 

0.35

9.4

0.50

10.6

0.68

11.7

0.85

12.7

1.03

13.6

1.25

14.4

1.46

14.9

 

1.69

15.1

 

1.92

15.0

 

2.15

1200

8.3

 

0.42

9.8

0.59

11.0

0.78

12.0

0.95

13.0

1.15

13.9

1.36

14.8

1.58

15.5

 

1.82

16.0

 

2.06

16.4

 

2.31

1300

8.8

 

0.51

10.2

0.69

11.3

0.88

12.4

1.08

13.3

1.28

14.2

1.49

15.0

1.72

15.8

 

1.96

16.5

 

2.21

17.1

 

2.47

1400

9.2

 

0.60

10.6

0.80

11.7

0.99

12.7

1.22

13.7

1.42

14.5

1.63

15.3

1.87

16.1

 

2.12

16.9

 

2.38

Ð

 

Ð

1500

9.7

 

0.71

11.0

0.91

12.1

1.12

13.0

1.35

14.0

1.59

14.8

1.81

15.6

2.04

16.4

 

2.30

Ð

 

Ð

Ð

Ð

1600

10.1

 

0.82

11.3

1.04

12.5

1.28

13.4

1.49

14.3

1.75

15.2

2.00

15.9

2.24

Ð

 

Ð

Ð

Ð

Ð

Ð

 

 

1700

10.6

 

0.93

11.8

1.20

12.9

1.44

13.8

1.67

14.7

1.92

15.5

2.20

Ð

Ð

Ð

Ð

Ð

Ð

 

Ð

Ð

 

 

Table 7 Ð Fan Performance (SI), 50LJQ012 (50 Hz) Ð Horizontal Discharge Units

AIRFLOW

 

 

 

 

 

 

 

 

EXTERNAL STATIC PRESSURE (Pa)

 

 

 

 

 

 

 

 

 

 

 

50

100

150

200

250

300

350

400

450

500

(L/s)

 

 

r/s

 

BkW

r/s

BkW

r/s

BkW

r/s

BkW

r/s

BkW

r/s

BkW

r/s

BkW

r/s

 

BkW

r/s

 

BkW

r/s

 

BkW

1300

7.6

 

0.30

8.9

0.41

10.2

0.56

11.1

0.64

12.1

0.77

13.1

0.92

13.9

0.93

14.0

 

0.52

15.0

 

1.13

15.6

 

1.32

1400

8.0

 

0.40

9.3

0.51

10.5

0.64

11.4

0.75

12.4

0.88

13.3

1.01

14.1

1.11

14.6

 

0.96

15.4

 

1.32

16.0

 

1.42

1500

8.4

 

0.48

9.6

0.60

10.7

0.72

11.8

0.86

12.7

0.99

13.5

1.12

14.3

1.26

15.1

 

1.35

15.7

 

1.49

16.4

 

1.54

1600

8.8

 

0.58

10.0

0.69

11.1

0.82

12.1

0.96

12.9

1.10

13.8

1.24

14.5

1.38

15.3

 

1.54

16.0

 

1.64

16.7

 

1.72

1700

9.1

 

0.69

10.3

0.78

11.3

0.93

12.3

1.07

13.2

1.22

14.0

1.37

14.8

1.52

15.5

 

1.66

16.3

 

1.84

17.0

 

1.95

1800

9.5

 

0.81

10.7

0.90

11.7

1.05

12.6

1.20

13.5

1.36

14.3

1.52

15.0

1.67

15.8

 

1.83

16.4

 

1.99

17.2

 

2.17

1900

9.9

 

0.95

11.0

1.02

12.0

1.18

12.9

1.34

13.8

1.50

14.6

1.68

15.3

1.83

16.0

 

2.00

16.7

 

2.16

17.3

 

2.33

2000

10.3

 

1.11

11.4

1.17

12.3

1.32

13.2

1.48

14.1

1.66

14.9

1.83

15.6

2.01

16.3

 

2.18

17.0

 

2.36

17.6

 

2.53

2100

10.7

 

1.29

11.8

1.33

12.7

1.47

13.5

1.65

14.4

1.84

15.1

2.00

15.9

2.20

16.6

 

2.38

Ð

 

Ð

Ð

Ð

2200

11.2

 

1.48

12.1

1.51

13.1

1.64

13.9

1.83

14.6

2.01

15.4

2.20

16.2

2.38

Ð

 

Ð

Ð

Ð

Ð

Ð

 

 

2300

11.6

 

1.70

12.5

1.71

13.4

1.83

14.2

2.01

15.0

2.20

15.7

2.41

Ð

Ð

Ð

Ð

Ð

Ð

 

Ð

Ð

 

 

Table 8 Ð Fan Performance (SI), 50LJQ008 (50 Hz) Ð Vertical Discharge Units

AIRFLOW

 

 

 

 

 

 

 

 

EXTERNAL STATIC PRESSURE (Pa)

 

 

 

 

 

 

 

 

 

 

 

50

100

150

200

250

300

350

400

450

500

(L/s)

 

 

r/s

 

BkW

r/s

BkW

r/s

BkW

r/s

BkW

r/s

BkW

r/s

BkW

r/s

BkW

r/s

 

BkW

r/s

 

BkW

r/s

 

BkW

1100

8.7

 

0.42

10.1

0.59

11.1

0.75

12.2

0.93

13.1

1.12

14.0

1.30

14.8

1.51

15.7

 

1.77

16.4

 

2.02

17.2

 

2.35

1200

9.3

 

0.52

10.5

0.69

11.6

0.87

12.6

1.05

13.5

1.26

14.3

1.46

15.1

1.66

15.9

 

1.88

16.7

 

2.14

17.4

 

2.44

1300

9.8

 

0.64

11.0

0.81

12.1

1.01

13.0

1.20

13.9

1.41

14.7

1.63

15.5

1.84

16.2

 

1.98

16.9

 

2.29

17.6

 

2.56

1400

10.4

 

0.77

11.5

0.94

12.6

1.16

13.5

1.37

14.3

1.58

15.1

1.80

15.9

2.04

16.6

 

2.27

17.3

 

2.51

Ð

 

Ð

1500

11.0

 

0.92

12.0

1.10

13.0

1.33

13.9

1.56

14.7

1.78

15.5

2.00

16.3

2.25

17.0

 

2.50

Ð

 

Ð

Ð

Ð

1600

11.6

 

1.08

12.6

1.28

13.5

1.50

14.4

1.76

15.2

2.00

16.0

2.23

16.7

2.47

Ð

 

Ð

Ð

Ð

Ð

Ð

 

 

1700

12.2

 

1.26

13.1

1.48

14.0

1.70

14.9

1.97

15.7

2.23

16.4

2.48

Ð

Ð

Ð

Ð

Ð

Ð

 

Ð

Ð

 

 

Table 9 Ð Fan Performance (SI), 50LJQ012 (50 Hz) Ð Vertical Discharge Units

AIRFLOW

 

 

 

 

 

 

 

 

EXTERNAL STATIC PRESSURE (Pa)

 

 

 

 

 

 

 

 

 

 

50

100

150

200

250

300

350

400

450

500

(L/s)

 

 

r/s

 

BkW

r/s

BkW

r/s

BkW

r/s

BkW

r/s

BkW

r/s

BkW

r/s

 

BkW

r/s

 

BkW

r/s

 

BkW

r/s

BkW

1300

8.4

 

0.37

9.6

0.51

10.8

0.61

11.7

0.69

12.6

0.81

13.3

0.90

14.3

 

1.05

15.1

 

1.27

15.9

 

1.48

16.7

1.67

1400

8.8

 

0.46

10.0

0.59

11.1

0.71

12.0

0.82

12.9

0.93

13.7

1.04

14.5

 

1.17

15.4

 

1.35

16.2

 

1.56

16.8

1.75

1500

9.2

 

0.55

10.4

0.68

11.5

0.81

12.4

0.94

13.2

1.06

14.0

1.19

14.8

 

1.26

15.6

 

1.44

16.4

 

1.62

17.1

1.83

1600

9.7

 

0.65

10.8

0.79

11.8

0.93

12.8

1.07

13.6

1.19

14.4

1.33

15.1

 

1.46

15.8

 

1.59

16.5

 

1.72

17.3

1.91

1700

10.2

 

0.75

11.2

0.91

12.2

1.06

13.1

1.20

13.9

1.34

14.7

1.48

15.4

 

1.63

16.1

 

1.76

16.7

 

1.89

17.4

2.04

1800

10.6

 

0.87

11.7

1.05

12.6

1.20

13.5

1.35

14.3

1.51

15.0

1.65

15.7

 

1.80

16.4

 

1.95

17.1

 

2.10

17.7

2.24

1900

11.1

 

1.01

12.1

1.19

13.0

1.35

13.9

1.52

14.7

1.68

15.4

1.84

16.1

 

1.99

16.8

 

2.14

17.4

 

2.31

18.0

2.46

2000

11.6

 

1.16

12.5

1.35

13.4

1.52

14.3

1.69

15.0

1.86

15.8

2.04

16.5

 

2.21

17.1

 

2.36

17.7

 

2.53

Ð

Ð

2100

12.0

 

1.32

13.0

1.53

13.8

1.70

14.6

1.88

15.4

2.07

16.1

2.25

16.8

 

2.43

Ð

 

Ð

Ð

Ð

Ð

Ð

 

2200

12.5

 

1.50

13.4

1.71

14.3

1.91

15.1

2.09

15.8

2.29

16.5

2.48

Ð

 

Ð

Ð

Ð

Ð

Ð

 

Ð

Ð

 

2300

13.0

 

1.70

13.9

1.91

14.7

2.13

15.5

2.31

16.2

2.52

Ð

Ð

Ð

Ð

Ð

Ð

 

Ð

Ð

 

Ð

Ð

 

 

LEGEND

r/s Ð

Wheel Speed (Revolutions per Second)

Bkw Ð

Fan Shaft Power (kW)

NOTES:

1.Boldface indicates ®eld-supplied drive required.

2. indicates ®eld-supplied motor and drive required.

3.Maximum usable output power (BkW) on the 50LJQ008 unit is 1.79 (2.40 Bhp) with standard 1.12 BkW (1.5 hp) motor. The maximum usable output power (BkW) increases to 2.16 (2.90 Bhp) on the 50LJQ012 unit with standard 1.5 BkW (2 hp) motor. Extensive

motor and electrical testing on the Weathermaker I units ensures that the full power range of the motor can be utilized with con®- dence. Using the fan motors up to the power ratings shown will not result in nuisance tripping or premature motor failure. Unit war- ranty will not be affected.

4.Use of ®eld-supplied motor may affect wire sizing. Contact Carrier representative to verify.

5.Values include losses for ®lters, unit casings and wet coils.

6.Motor drive range is 10.30 to 14.70 r/s (622 to 882 rpm) on the 50LJQ008 and 11.50 to 15.00 r/s (692 to 896 rpm) on the 50LJQ012. All other r/s (rpms) will require a ®eld-supplied drive.

15

Image 15
Contents Installation, Start-Up and Service Instructions PKG. ACC Roof Curb ``A Unit Size AccessoryUnit Size ``F Power Connector50LJQ Unit MAX Dimensions WeightÐ Physical Data SI Base Unit 50QJ Ð Physical Data English``H ``J Weight ``BWeight ``D 50LJQ Unit STD. Unit Economizer CornerEquip GNDHTR Page Equip Equip Electrical Data American/European Wire Conversions Unit VoltageAmerican European DAT Unit Heater Required ConfigBAT OFC50LJQ Motor Pulley Turns Open Ð Fan Rpm at Motor Pulley Settings EnglishAirflow 2400 482 External Static Pressure in. wgRpm Bhp 2200 459START-UP OFC Ð Outdoor-Fan Contactor ContactorHeater Contactor OAT Ð Outdoor-Air ThermostatService Lubrication Cooling Charging Charts, 50LJQ008 Page Page Copyright 1992 Carrier Corporation

012, 50LJQ008 specifications

The Carrier 012,50LJQ008 is a state-of-the-art air conditioning unit, specifically designed to provide optimal temperature control and energy efficiency for residential and commercial applications. As part of Carrier's renowned portfolio, this model incorporates innovative technologies and user-friendly features that set it apart from competitors in the market.

One of the standout characteristics of the Carrier 012,50LJQ008 is its high energy efficiency rating. Equipped with advanced inverter technology, this unit adjusts its cooling output based on the ambient temperature and humidity levels, reducing energy consumption while maintaining consistent comfort. This not only lowers utility bills but also minimizes the environmental impact, making it a sustainable choice for modern living.

In terms of cooling capacity, the Carrier 012,50LJQ008 offers a formidable performance, capable of efficiently cooling spaces of varying sizes. Its robust compressor ensures rapid cooling while remaining remarkably quiet, which is particularly advantageous for residential settings. The unit’s capacity to handle high ambient temperatures allows it to perform reliably even in extreme weather conditions, ensuring comfort during the hottest days of summer.

Another key feature is the user-friendly interface. The Carrier 012,50LJQ008 comes with a digital control panel that allows users to easily set their desired temperature and adjust fan speeds according to their preferences. Additionally, it offers remote control functionality, providing convenience and ease of use for homeowners and occupants alike.

The design of the Carrier 012,50LJQ008 incorporates advanced air filtration technology, including a multi-layer filter system that captures allergens and airborne particles. This not only improves indoor air quality but also contributes to the longevity of the unit by preventing dust buildup. The filters are easily accessible for cleaning and replacement, ensuring the system runs efficiently.

Durability is another critical aspect of this model. Constructed with high-quality materials, the Carrier 012,50LJQ008 is designed to withstand varying environmental conditions. Its corrosion-resistant outdoor unit ensures a longer lifespan, while comprehensive warranties provide peace of mind to users.

In summary, the Carrier 012,50LJQ008 is an exemplary air conditioning unit that combines energy efficiency, advanced technology, and user-centric features. Whether for a family home or a commercial space, its superior performance, reliability, and ease of use make it an excellent choice for maintaining optimal comfort year-round.