Sun Microsystems 6900, 3900 manual Sun StorEdge T3+ Array Partner Group Error Messages

Models: 6900 3900

1 204
Download 204 pages 8.57 Kb
Page 191
Image 191
Sun StorEdge T3+ Array Partner Group Error Messages

Sun StorEdge T3+ Array Partner Group Error Messages

Caution Running restoret3config(1M) or modifyt3config(1M) destroys all data on the Sun StorEdge T3+ array.

TABLE B-3Sun StorEdge T3+ Array Error Messages

Source of Error Message

Cause of Error Message

Suggested Corrective Action

 

 

 

 

Common to Sun

• The current configuration does not

1.

Check the current Sun StorEdge

StorEdge T3+ array

match the reference (standard)

 

T3+ array configuration with the

 

configurations.

 

showt3 -n <t3> command.

 

• This particular configuration is not

2.

Verify whether the configuration

 

a standard, supported type.

 

is corrupted or has changed.

 

 

3. Refer to the raid.cfg files in

 

 

 

/opt/SUNWsecfg/etc to

 

 

 

determine if the configuration

 

 

 

commands are set up and

 

 

 

functioning properly.

 

 

 

 

Common to Sun

• Could not mount volume

1.

Replace the failed FRUs.

StorEdge T3+ array

$volume

2.

Restore the Sun StorEdge T3+

 

$lun config does not match

 

array configuration with the

 

• The LUN might have multiple

 

restoret3config -f -n

 

drive failures or corrupted data or

 

t3_name command.

 

parity.

 

 

 

 

 

Common to Sun

• No volumes exist on this Sun

Create and restore the Sun StorEdge

StorEdge T3+ array

StorEdge T3+ array.

T3+ array LUNs using

 

$volume volume not found on

restoret3config(1M) or

 

this Sun StorEdge T3+ array.

modifyt3config(1M).

 

 

 

Common to Sun

• The $fru status is not ready or

The disk, controller, or loop interface

StorEdge T3+ array

enabled.

card in the Sun StorEdge T3+ array

 

• Operations on the Sun StorEdge

might be faulty. Replace the failed

 

T3+ array are being aborted.

FRU and rerun the utility.

 

 

 

 

Appendix B Configuration Utility Error Messages 171

Sun Proprietary/Confidential: Internal Use Only

Page 191
Image 191
Sun Microsystems 6900 Sun StorEdge T3+ Array Partner Group Error Messages, Sun Proprietary/Confidential Internal Use Only