TABLE B-3Sun StorEdge T3+ Array Error Messages (Continued)

Source of Error Message

Cause of Error Message

Suggested Corrective Action

 

 

 

 

checkt3mount

• The $lun status reported a bad or

1.

Run the showt3 -ncommand to

 

nonexistent LUN.

 

verify that the requested LUN

 

• While checking the configuration

 

exists on the Sun StorEdge T3+

 

using the showt3 -ncommand,

 

array.

 

operations abort.

2.

Confirm that the Sun StorEdge

 

 

 

T3+ array configuration matches

 

 

 

standard configurations.

 

 

 

createt3group

User-specified LUN $lun does not

Create the required slice or LUN

 

exist on the Sun StorEdge T3+ array.

before you set permissions using the

 

 

createt3slice command.

 

 

 

createt3group

Unable to set permissions on the

Refer to the Sun StorEdge T3 and T3+

 

LUN $lun to $perm for new group.

array documentation.

 

 

 

createt3group

Error while resetting permissions on

Refer to the Sun StorEdge T3 and T3+

 

LUN $lun to NONE for group

array documentation.

 

$group.

 

 

 

 

 

delfromt3group

Error deleting the world wide name

Refer to the Sun StorEdge T3 and T3+

 

(WWN) $wwn from group.

array documentation.

 

 

 

 

enablevolslicing

Error checking the Sun StorEdge T3+

1.

Check the Sun StorEdge T3+ array

 

enable volume slicing status.

 

firmware level and verify it is

 

 

 

2.01.00 or higher.

 

 

2.

Check if volume slicing is

 

 

 

supported and enabled on the Sun

 

 

 

StorEdge T3+ array.

 

 

 

 

enablevolslicing

Cannot enable volume slicing. The

1.

Check the Sun StorEdge T3+ array

 

Sun StorEdge T3+ array firmware

 

firmware level and verify it is

 

does not support this feature.

 

2.01.00 or higher.

 

 

2.

Upgrade the firmware, if required.

 

 

 

 

modifyt3config

• The lock file clear waiting period

1.

Check to see if any secfg T3+

 

expired.

 

commands are being executed.

 

• The creatediskpools command

2.

If the commands are executing,

 

aborted.

 

wait for them to complete.

 

 

3.

Run creatediskpools -n

 

 

 

t3name.

 

 

 

restoret3config

• An error occurred while the block

Run the restoret3config

 

size compare command was

command.

 

executing.

 

 

 

• The Sun StorEdge T3+ array block

 

 

 

size parameter is different from the

 

 

 

snapshot file. The Sun StorEdge T3+

 

 

 

array may have been reconfigured.

 

 

 

 

 

 