FRU Tests Available for the T1 or T2 Data Path FRU
FIGURE 8-4

FRU Tests Available for the T1 or T2 Data Path FRU

Running the tests from the Storage Automated Diagnostic Environment GUI guides you in discovering the failed FRU. Refer to Chapter 5 of the Storage Automated Diagnostic Environment User’s Guide for instructions on how to run tests.

Run the switchtest to test the switches.

Run the linktest to test the T1 or T2 connections.

After a test has completed its run, an email message similar to the message in is sent to the specified email recipient.

running on diag.xxxxx.xxx.com

linktest started on FC interconnect: switch to switch switchtest started on switch 100000c0dd00b682 port 8 Estimated test time 14 minute(s)

01/30/02 11:21:26 diag209 Storage Automated Diagnostic Environment: MSGID 6013 switchtest.FATAL

switch0: "Device: Switch Port: 8 is Offline"

switchtest failed

Remove FC Cable from switch: 100000c0dd00b682, port: 8

Insert FC loopback cable into switch: 100000c0dd00b682, port: 8 Continue Isolation ?

switchtest started on switch 100000c0dd00b682 port 8 Estimated test time 14 minute(s)

01/30/02 11:22:11 diag209 Storage Automated Diagnostic Environment: MSGID 6013 switchtest.FATAL

switch0: "Device: Switch Port: 8 is Offline"

switchtest failed

Remove FC loopback cable from switch: 100000c0dd00b682, port: 8

Insert a NEW FC GBIC into switch: 100000c0dd00b682, port: 8

Insert FC loopback cable into switch: 100000c0dd00b682, port: 8 Continue Isolation ?

switchtest started on switch 100000c0dd00b682 port 8 Estimated test time 14 minute(s)

01/30/02 11:25:12 diag209 Storage Automated Diagnostic Environment: MSGID 4001 switchtest.WARNING

switch0: "Maximum transfer size for a FABRIC port is 200. Changing transfer size 2000 to 200"

switchtest completed successfully

Remove FC loopback cable from switch: 100000c0dd00b682, port: 8

Restore ORIGINAL FC Cable into switch: 100000c0dd00b682, port: 8

Suspect ORIGINAL FC GBIC in switch: 100000c0dd00b682, port: 8

Retest to verify FRU replacement.

linktest completed on FC interconnect: switch to switch

FIGURE 8-4Example Link Test Text Output from the Storage Automated Diagnostic Environment

Chapter 8 Troubleshooting the Sun StorEdge T3+ Array Devices 93

Sun Proprietary/Confidential: Internal Use Only

Page 113
Image 113