Verifying the Data Host

A problem in the A4 or B4 FC Link appears differently on the data host, depending on whether the array is a Sun StorEdge 3900 series or a Sun StorEdge 6900 series device.

Sun StorEdge 3900 Series

In a Sun StorEdge 3900 series device, the data host multipathing software is responsible for initiating the failover and reports it in /var/adm/messages, such as those reported by the Storage Automated Diagnostic Environment email notifications.

The luxadm failover command is used to fail the Sun StorEdge T3+ array LUNs back to the proper configuration after the failing FRU is replaced. This command is issued from the data host.

Sun StorEdge 6900 Series

In a Sun StorEdge 6900 series device, the virtualization engine pairs handle the failover and the failover is not noted on the data host. All paths remain online and active.

The failbackt3path command is used, and is issued from the Storage Service Processor.

Note In the event of a complete sw1b or sw2b failure in a Sun StorEdge 6900 series configuration, the virtualization engine pairs handle the failover. In addition, the multipathing software notes a path failure on the data host, the Sun StorEdge Traffic Manager or DMP software takes the entire path that was connected to the failed switch offline, and the Inter-Switch Link (ISL) ports on the surviving switch go offline as well.