Sun Microsystems 6900 FC Link Error Status Report, To Check the FC Link Error Status Manually

Models: 6900 3900

1 204
Download 204 pages 8.57 Kb
Page 133
Image 133
FC Link Error Status Report

FC Link Error Status Report

The virtualization engine’s host-side and device-side interfaces provide statistical data for the counts listed in TABLE 9-4.

TABLE 9-4Virtualization Engine Statistical Data

Count Type

Description

 

 

Link failure count

The number of times the virtualization engine’s frame manager

 

detects a nonoperational state or other failure of N port

 

initialization protocol.

Loss of

The number of times that the virtualization engine detects a loss in

synchronization

synchronization.

count

 

Loss of signal count

The number of times that the virtualization engine’s frame manager

 

detects a loss of signal.

Primitive sequence

The number of times that the virtualization engine’s frame manager

protocol error

detects N port protocol errors.

Invalid transmission

The number of times that the virtualization engine’s 8-bit and 10-bit

word

decoder does not detect a valid 10-bit code.

Invalid cyclic

The number of times that the virtualization engine receives frames

redundancy code

with a defective CRC and a valid EOF. A valid EOF includes EOFn,

(CRC) count

EOFt, or EOFdti.

 

 

To Check the FC Link Error Status Manually

The Storage Automated Diagnostic Environment, which runs on the Storage Service Processor, monitors the FC link status of the virtualization engine. The virtualization engine must be power-cycled to reset the counters. Therefore, you should manually check the accumulation of errors during a fixed period of time. To check the status manually, follow these steps:

1.Use the svstat command to take a reading, as shown in CODE EXAMPLE 9-1. A status report for the host-side and device-side ports is displayed.

2.Within the next few minutes, take another reading.

The number of new errors that occurred within that time frame represents the number of link errors.

Chapter 9 Troubleshooting Virtualization Engine Devices 113

Sun Proprietary/Confidential: Internal Use Only

Page 133
Image 133
Sun Microsystems 6900, 3900 manual FC Link Error Status Report, To Check the FC Link Error Status Manually