TABLE 9-5Storage Automated Diagnostic Environment Event Grid for Virtualization Engine (Continued)

Component

 

 

 

Required

 

EventType

Severity

Information

Action

 

 

 

 

 

 

oob.slicd

Comm_

Down

The virtualization engine

1.

Check the status of the slicd

 

Lost

 

failed to execute slicd

 

daemon.

 

 

 

command.

2.

Check the power on the

 

 

 

 

 

virtualization engine.

 

 

 

 

3.

Make sure the virtualization

 

 

 

 

 

engine is booted correctly.

 

 

 

 

4.

Verify that the TCP/IP

 

 

 

 

 

settings on the virtualization

 

 

 

 

 

engine are correct.

 

 

 

 

5.

Check the T3 message log for

 

 

 

 

 

failover conditions in the Sun

 

 

 

 

 

StorEdge T3+ array.

 

 

 

 

6.

Replace the virtualization

 

 

 

 

 

engine, if necessary.

 

 

 

 

 

 

oob.

Comm_

Down

Invalid command or slicd

1.

Check the status of the slicd

command

Lost

 

daemon problem.

 

daemon.

 

 

 

 

2.

Check the power on the

 

 

 

 

 

virtualization engine.

 

 

 

 

3.

Make sure the virtualization

 

 

 

 

 

engine is booted correctly.

 

 

 

 

4.

Verify that the TCP/IP

 

 

 

 

 

settings on the virtualization

 

 

 

 

 

engine are correct.

 

 

 

 

5.

Check the T3 message log for

 

 

 

 

 

failover conditions in the Sun

 

 

 

 

 

StorEdge T3+ array.

 

 

 

 

6.

Replace the virtualization

 

 

 

 

 

engine, if necessary.

 

 

 

 

 

 

134Sun StorEdge 3900 and 6900 Series 2.0 Troubleshooting Guide • March 2003