1.Discover the error by checking one or more of the following messages or files:

Storage Automated Diagnostic Environment alerts or email messages

/var/adm/messages

Sun StorEdge T3+ array syslog file

Storage Service Processor messages

/var/adm/messages.t3 messages

/var/adm/log/SEcfglog file

2.Determine the extent of the problem by using one or more of the following methods:

Review the Storage Automated Diagnostic Environment topology view.

Using the Storage Automated Diagnostic Environment revision checking functionality, determine whether the package or patch is installed.

Verify the functionality using one of the following tools:

checkdefaultconfig(1M)

cfgadm -al output

luxadm(1M) output

Review the multipathing status using the Sun StorEdge Traffic Manager (MPxIO) software or vxdmp(1M) command.

3.Check the status of a Sun StorEdge T3+ array by using one or more of the following methods:

Review the Storage Automated Diagnostic Environment device monitoring reports.

Run the checkt3config(1M) and showt3(1M) commands, which check and display the Sun StorEdge T3+ array configuration.

Manually open a Telnet session to the Sun StorEdge T3+ array.

Review the luxadm(1M) display output.

Review the LED status on the Sun StorEdge T3+ array.

Review the Explorer Data Collection Utility output, which is located on the Storage Service Processor.

4 Sun StorEdge 3900 and 6900 2.0 Series Troubleshooting Guide • March 2003