Troubleshooting the T1 or T2 Data Path

Troubleshooting the T1 or T2 Data Path

When you are troubleshooting the T1 or T2 data path, note the following:

Two T port links provide redundancy.

If one of the two links is lost, no Sun StorEdge T3+ array LUN failover occurs and no pathing failures are detected.

If both T port links fail, a Sun StorEdge T3+ array LUN failover occurs, as one of the virtualization engines takes control of the I/O operations. One of the Sun StorEdge T3+ array LUNs fail over, as all I/O is routed to the controlling virtualization engine.

The host detects a pathing failure in its multipathing software.

88 Sun StorEdge 3900 and 6900 Series 2.0 Troubleshooting Guide • March 2003