FIGURE 5-7A2 or B2 FC Link Storage Service Processor-Side Event

Site

: FSDE LAB Broomfield CO

Source

: diag.xxxxx.xxx.com

Severity : Normal

 

Category : Switch

Key: switch:100000c0dd0061bb

EventType: StateChangeEvent.X.port.1

EventTime: 01/08/2002 17:38:32

’port.1’

in SWITCH

diag-sw1b (ip=192.168.0.31) is now Unknown (status-

state changed from

’Online’ to ’Admin’):

----------------------------------------------------------------

Site

: FSDE LAB Broomfield CO

Source

: diag.xxxxx.xxx.com

Severity

: Normal

 

Category

: San

Key: switch:100000c0dd0061bb:1

EventType: LinkEvent.ITW.switchve

EventTime: 01/08/2002 17:39:47

ITW-ERROR (765 in 11 mins): Origin: port 1 on ’switch ’sw1b/192.168.0.31’.

Destination: port 1 on ve ’diag-v1b/29000060220041f4’: Info:

An invalid transmission word (ITW) was detected between two components. This could indicate a potential problem.

Cause:

Likely Causes are: GBIC, FC Cable and device optical connections. Action:

To isolate further please run the Storage Automated Diagnostic Environment tests associated with this link segment.