Sun Microsystems 6900, 3900 manual Sun Proprietary/Confidential Internal Use Only

Models: 6900 3900

1 204
Download 204 pages 8.57 Kb
Page 75
Image 75
FIGURE 5-9A3 or B3 FC Link Storage Service Processor-Side Event

Site

:

FSDE LAB Broomfield CO

Source

:

diag.xxxxx.xxx.com

Severity :

Normal

 

Category :

Switch

Key: switch:100000c0dd0057bd

EventType:

StateChangeEvent.M.port.1

EventTime:

01/08/2002 18:28:38

’port.1’ in SWITCH diag-sw1a (ip=192.168.0.30) is now Not-Available (status-state changed from ’Online’ to ’Offline’):

Info:

A port on the switch has logged out of the fabric and gone offline Action:

1.Verify cables, GBICs and connections along FC path

2.Check Storage Automated Diagnostic Environment SAN Topology GUI to identify failing segment of the data path

3.Verify correct FC switch configuration

FIGURE 5-9A3 or B3 FC Link Storage Service Processor-Side Event

Site

:

FSDE LAB Broomfield CO

Source

:

diag.xxxxx.xxx.com

Severity :

Normal

 

Category :

Switch

Key: switch:100000c0dd00cbfe

EventType:

StateChangeEvent.M.port.1

EventTime:

01/08/2002 18:28:40

’port.1’ in SWITCH diag-sw2a (ip=192.168.0.32) is now Not-Available (status-state changed from ’Online’ to ’Offline’):

Info:

A port on the switch has logged out of the fabric and gone offline Action:

1.Verify cables, GBICs and connections along FC path

2.Check Storage Automated Diagnostic Environment SAN Topology GUI to identify failing segment of the data path

3.Verify correct FC switch configuration

FIGURE 5-10A3 or B3 FC Link Storage Service Processor-Side Event

Chapter 5 Troubleshooting the Fibre Channel (FC) Links 55

Sun Proprietary/Confidential: Internal Use Only

Page 75
Image 75