Page 73
Image 73
6. Return the path to production.

5.If the switch and the GBIC show no errors, replace the remaining components in the following order:

a.Replace the virtualization engine-side GBIC, recable the link, and monitor the link for errors.

b.Replace the cable, recable the link, and monitor the link for errors.

c.Replace the virtualization engine, restore the virtualization engine settings, recable the link, and monitor the link for errors.

Note The procedures for restoring virtualization engine settings are in the Sun StorEdge 3900 and 6900 Series 2.0 Reference and Service Guide.

6. Return the path to production.

Chapter 5 Troubleshooting the Fibre Channel (FC) Links 53

Sun Proprietary/Confidential: Internal Use Only