Sun Microsystems 6900, 3900 manual Sun Proprietary/Confidential Internal Use Only, State, Offline

Models: 6900 3900

1 204
Download 204 pages 8.57 Kb
Page 83
Image 83
#/usr/sbin/luxadm display /dev/rdsk/c26t60020F200000644>

To verify that the failover luxadm display can be used, the failed path is marked “offline,” as shown in CODE EXAMPLE 5-7.

CODE EXAMPLE 5-7Failed Path Marked Offline

#/usr/sbin/luxadm display /dev/rdsk/c26t60020F200000644>

DEVICE PROPERTIES for disk: /dev/rdsk/ c26t60020F20000064433C3352A60003E82Fd0s2

Status(Port

A):

O.K.

Status(Port

B):

O.K.

Vendor:

 

SUN

Product ID:

 

T300

WWN(Node):

 

50020f2000006443

WWN(Port A):

50020f2300006355

WWN(Port B):

50020f2300006443

Revision:

 

0118

Serial Num:

 

Unsupported

Unformatted

capacity:

488642.000 MBytes

Write Cache:

Enabled

Read Cache:

 

Enabled

Minimum prefetch:

0x0

Maximum prefetch:

0x0

Device Type:

Disk device

Path(s):

 

 

/dev/rdsk/c26t60020F20000064433C3352A60003E82Fd0s2 /devices/scsi_vhci/ssd@g60020f20000064433c3352a60003e82f:c,raw

Controller

/devices/pci@a,2000/pci@2/SUNW,qlc@5/fp@0,0

Device Address

50020f2300006355,1

Class

primary

State

OFFLINE

Controller

/devices/pci@e,2000/pci@2/SUNW,qlc@5/fp@0,0

Device Address

50020f2300006443,1

Class

secondary

State

ONLINE

Note This type of error may also cause the device to show up as "unusable" in cfgadm, as shown in CODE EXAMPLE 5-8.

Chapter 5 Troubleshooting the Fibre Channel (FC) Links 63

Sun Proprietary/Confidential: Internal Use Only

Page 83
Image 83
Sun Microsystems 6900 Sun Proprietary/Confidential Internal Use Only, Troubleshooting the Fibre Channel FC Links, State