Sun Microsystems 3900, 6900 manual Sun Proprietary/Confidential Internal Use Only

Models: 6900 3900

1 204
Download 204 pages 8.57 Kb
Page 162
Image 162
The Multipath Configurator LUN Properties detail window is displayed.

c.To view details about the Sun StorEdge T3+ Array paths, click the Details button.

The Multipath Configurator LUN Properties detail window is displayed.

FIGURE 10-6Multipath Configurator LUN Properties Detail

Note From this example, note the Primary Path is Unknown and the Alternate Path is currently in use.

To Use the Sun StorEdge T3+ Array Failover Driver Command Line Interface (CLI)

Use the jafo_nutil.exe interface, which is available with Sun StorEdge T3+ Array Failover Driver version 2.1 and later, to gather information about:

The WWN of monitored Sun StorEdge T3+ array partner groups

The WWN of individual LUNs

Device paths

LUN to drive letter mapping

The status for

primary paths

secondary paths

standby paths

active paths

In addition, you can use the jafo_nutil.exe interface to perform failback operations in recovery scenarios.

Although the Sun StorEdge T3+ Array Failover Driver GUI is limited to the Sun StorEdge 3900 series systems, you can use the CLI for both the Sun StorEdge 3900 series systems and the Sun StorEdge 6900 series systems.

142Sun StorEdge 3900 and 6900 Series 2.0 Troubleshooting Guide • March 2003

Sun Proprietary/Confidential: Internal Use Only

Page 162
Image 162
Sun Microsystems 3900, 6900 manual Sun Proprietary/Confidential Internal Use Only