Image 173
6.Recover the problem with the GBIC or the switch.

The first run failed, indicating a problem with either the GBIC or with the Sun StorEdge network FC switch.

To further isolate the problem, a new GBIC was inserted into the port, the loopback connector was re-inserted, and the same test was run a second time.

FIGURE 11-8Successful Switch Test Results

On this pass, the test was successful. This indicates that the problem was most likely the switch-side GBIC, which was replaced.

6.Recover the problem with the GBIC or the switch.

a.Recable the link between the HBA and switch.

b.Use the Sun StorEdge T3+ Array Failover Driver GUI for the Sun StorEdge 3900 series system, or the CLI for the 6900 series, to recover the multipathing.

Chapter 11 Example of Fault Isolation 153

Sun Proprietary/Confidential: Internal Use Only